{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F05410","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F05410","canonicalUrl":"https://aoctrl.com/schneider/A9F05410","factsUrl":"https://aoctrl.com/api/mcp/products/A9F05410","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, A9F05410, miniature circuit-breaker, 4P, 10 A, D-curve, 36 kA Icu at 133 V AC, thermal-magnetic, DIN-rail mount.","salesMarkdown":"The A9F05410 is a 4-pole (4P) miniature circuit-breaker from the Acti9 iC60N series, rated 10 A with a D-curve — magnetic trip at 12 x In (±20 %), so it handles inrush from motor loads, transformers, or welding equipment without nuisance tripping on startup. The thermal-magnetic trip unit covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one package. Breaking capacity hits 36 kA Icu at 12–133 V AC (EN/IEC 60947-2), enough for high-fault panels near substations; derates to 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V. Under EN/IEC 60898-1 it's rated 10 kA Icn at 400 V — the standard for domestic/commercial distribution boards. That dual-standard certification (60947-2 for industrial, 60898-1 for distribution) means it qualifies for either a control-panel feeder or a sub-distribution board. Snaps onto standard DIN rail — 9 mm pitch occupies 8 modules (72 mm wide), which is the space footprint to budget in your enclosure layout. Double terminals top and bottom accept 1–25 mm² rigid or 1–16 mm² flexible; strip 14 mm and torque to 2 N·m. Listed as current-production lifecycle stage. The Acti9 iC60N platform is Schneider's mainstream MCB line.","metaTitle":"A9F05410 Acti9 iC60N MCB, 10 A, Curve D, 4P, 36 kA","metaDescription":"Schneider Electric A9F05410 Acti9 iC60N miniature circuit-breaker, 10 A rated current, D-curve, 4-pole, 36 kA breaking capacity at 133 V AC. DIN-rail mount, thermal-magnetic trip.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/10953f3282af872f3ddbd792cf56e7f6.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F05410/miniature-circuit-breaker-mcb-acti9-ic60n-4p-10a-d-curve-6000a-iec-608981-10ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F05410/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F05410?","answer":"Breaking capacity is 36 kA Icu at 12–133 V AC (EN/IEC 60947-2), 20 kA at 220–240 V, 10 kA at 380–415 V, 6 kA at 440 V, and 10 kA Icn at 400 V (EN/IEC 60898-1)."},{"question":"What curve and rated current does A9F05410 have?","answer":"D-curve with magnetic trip at 12 x In (±20 %), rated 10 A. The D-curve is sized for loads with high inrush — motors, transformers, welding plant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F05410","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F05410 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}