{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06113","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06113","canonicalUrl":"https://aoctrl.com/schneider/A9F06113","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06113","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, 1P, 13 A, B curve, 42 kA Icu at 12-60 VAC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F06113 is an Acti9 iC60H miniature circuit breaker — a 1-pole, 13 A thermal-magnetic MCB with a B-curve trip characteristic. ## Breaking capacity and what it means for your panel The A9F06113 carries a 42 kA Icu at 12-60 VAC (50/60 Hz) per EN/IEC 60947-2, and 30 kA at 100-133 VAC, 15 kA at 220-240 VAC. On DC circuits it delivers 20 kA Icu at 12-60 VDC and 15 kA at 60-72 VDC. The Icn rating under EN/IEC 60898-1 is 10,000 A at 230 VAC. Snap-on DIN rail mounting (per) — 18 mm per pole width, 91 mm height, 78.5 mm depth. Two 9 mm pitches occupied. Double terminals top and bottom accept 1-25 mm² rigid or 1-16 mm² flexible copper. Tightening torque 2 N·m. IP20 finger-safe terminals; pollution degree 3 rated for the industrial environment inside the enclosure.","metaTitle":"Schneider Electric A9F06113 Acti9 iC60H MCB, 13 A, Curve B,","metaDescription":"Schneider Electric A9F06113 Acti9 iC60H miniature circuit breaker, 13 A rated current, B-curve, 1-pole, 42 kA breaking capacity at 12-60 VAC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 20 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 15 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/43ef128d027d4f383feba0bdaf04f300.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06113/miniature-circuit-breaker-mcb-acti9-ic60h-1p-13a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06113/alternatives.json"},"ai":{"faq":[{"question":"What is A9F06113's listed range?","answer":"Acti9 — Schneider Electric's modular DIN-rail protection range for final distribution."},{"question":"What compliance documentation does Schneider provide for A9F06113?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries an IP20 protection rating and is tropicalised per IEC 60068-1 (2 levels). RoHS and REACH compliance documentation is standard for the Acti9 range; request it with your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06113","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06113 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}