{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06163","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06163","canonicalUrl":"https://aoctrl.com/schneider/A9F06163","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06163","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, A9F06163, 1-pole miniature circuit breaker, 63 A rated, B-curve, thermal-magnetic trip, DIN rail mount, 42 kA breaking capacity at 12-60 VAC.","salesMarkdown":"## What the 63 A B-curve rating means for your panel The A9F06163 is a 1-pole Acti9 iC60H miniature circuit breaker rated 63 A with a B-curve trip characteristic — magnetic tripping at 4 x In (±20 %), so it clears short-circuits between 252 A and 302 A. The thermal-magnetic trip unit handles the overload side; the magnetic element handles the short-circuit side. It's dual-rated to EN/IEC 60947-2 (utilisation category A) and EN/IEC 60898-1, so it can serve either distribution board or industrial panel duty — the 60947-2 rating gives you the higher breaking capacities for industrial coordination studies. ## Breaking capacity — the number that governs fault coordination The iC60H frame carries a 42 kA Icu at 12-60 VAC, 30 kA at 100-133 VAC, and 15 kA at 220-240 VAC (per EN/IEC 60947-2). On DC: 20 kA at 12-60 VDC, 15 kA at 60-72 VDC. Under the 60898-1 standard for household-type installations, it's rated 10,000 A Icn at 230 VAC. That's a high-interrupting-capacity (H) frame — useful if you're coordinating downstream of a transformer or in a high-fault location. ## Mounting and integration — drops into a standard DIN rail slot Snap-on DIN rail mount, 18 mm width (2 x 9 mm pitches), 91 mm height, 78.5 mm depth. That's a standard 1-pole modular width — it occupies one slot in any Acti9 or third-party distribution board. The double terminals accept 1-35 mm² rigid or 1-25 mm² flexible on top or bottom. Wire strip length 14 mm. IP20 finger-safe protection. The white housing with toggle and trip indicator gives local status at a glance.","metaTitle":"Schneider Electric A9F06163 Acti9 iC60H MCB, 63 A, 1P, B Cur","metaDescription":"Schneider A9F06163 Acti9 iC60H miniature circuit breaker, 63 A rated, 1-pole, B curve, 42 kA breaking capacity at 12-60 VAC. Dual-rated EN/IEC 60947-2 and 60898-1. Current producti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 20 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 15 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d684cd145c79fb891e2d9fec3750200c.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06163/miniature-circuit-breaker-mcb-acti9-ic60h-1p-63a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06163/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F06163 and how do I get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is A9F06163's listed depth (78.5 mm) on this component line?","answer":"The overall depth is 78.5 mm, which includes the body and toggle mechanism. That's within the standard profile for a 1-pole Acti9 iC60H MCB — it fits most distribution boards and enclosures without depth clearance issues."},{"question":"What is A9F06163's listed range (Acti9) on this component line?","answer":"It belongs to the Acti9 range, Schneider Electric's modular DIN-rail distribution product family. The specific device short name is iC60H — the 'H' denotes the high-interrupting-capacity frame (up to 42 kA)."},{"question":"What compliance documentation does this brand provide for A9F06163 (RoHS, REACH, UL, IEC)?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries tropicalisation treatment per IEC 60068-1 (class 2). For RoHS/REACH declarations and any UL listing status, those are typically available from the manufacturer's product documentation portal — the evidence on hand confirms IEC compliance and the dual standard rating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06163","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06163 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}