{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06213","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06213","canonicalUrl":"https://aoctrl.com/schneider/A9F06213","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06213","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F06213, 2P, 13 A, curve B, 42 kA Icu at 12-133 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F06213 is a 2-pole, 13 A miniature circuit-breaker from the Acti9 iC60H series, with a B-curve trip characteristic. The 42 kA Icu at 12-133 V AC (30 kA at 220-240 V, 15 kA at 380-415 V) means it can safely interrupt high fault currents without upstream cascading — a key spec for high-available-fault installations. Width is 36 mm (4 x 9 mm pitches), depth 78.5 mm, height 91 mm. IP20 rated, pollution degree 3. Current-production part — no end-of-life notice on record.","metaTitle":"Schneider A9F06213 Acti9 iC60H MCB, 13 A, 2P, Curve B, 42 kA","metaDescription":"Schneider Electric A9F06213 Acti9 iC60H miniature circuit-breaker, 13 A rated current, 2 poles, curve B, 42 kA breaking capacity at 12-133 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/78978c727d765e43b4294ab62c50a36a.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06213/miniature-circuit-breaker-mcb-acti9-ic60h-2p-13a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06213/alternatives.json"},"ai":{"faq":[{"question":"What is A9F06213's listed depth?","answer":"The depth is 78.5 mm."},{"question":"What is A9F06213's listed range?","answer":"It belongs to the Acti9 range from Schneider Electric."},{"question":"What compliance documentation does Schneider provide for A9F06213?","answer":"The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1, and carries tropicalisation class 2 per IEC 60068-1. Specific RoHS/REACH/UL declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06213","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06213 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}