{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06263","canonicalUrl":"https://aoctrl.com/schneider/A9F06263","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, 63 A, 2P, B-curve, 42 kA breaking capacity at 12-133 V AC, DIN rail mount, white.","salesMarkdown":"## What this 63 A breaker does on the line The A9F06263 is a 63 A, 2-pole B-curve miniature circuit breaker from Schneider Electric's Acti9 iC60H family. The B-curve trips magnetically at 4 x In (±20 %), so it's a good fit for resistive or general-purpose distribution loads where you don't want nuisance trips from motor inrush. ## Rated for distribution, dual-certified This breaker carries both EN/IEC 60898-1 (domestic / building wiring) and EN/IEC 60947-2 (industrial distribution) certifications. That dual stamp means it's accepted in residential panels and industrial switchboards alike — one SKU for both sides of the meter. The double-terminal design lets you daisy-chain a feed-through without piggyback lugs — handy when you're feeding a downstream meter or RCCB on the same DIN rail.","metaTitle":"A9F06263 Acti9 iC60H MCB, 63 A, 2P, B-Curve, 42 kA","metaDescription":"Schneider Electric A9F06263 Acti9 iC60H miniature circuit breaker, 63 A, 2 poles, B-curve, 42 kA breaking capacity at 12-133 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c6f31b4f27d95399d33536947552c0bb.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06263/miniature-circuit-breaker-mcb-acti9-ic60h-2p-63a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06263/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F06263 at 400 V?","answer":"At 380-415 V AC it's rated 15 kA Icu per EN/IEC 60947-2, and at 400 V AC it also carries a 10 kA Icn rating per EN/IEC 60898-1 — so it's suitable for most European 400 V distribution panels where the prospective fault current stays under 10 kA."},{"question":"What standards does A9F06263 comply with?","answer":"It is certified to both EN/IEC 60947-2 and EN/IEC 60898-1, making it acceptable for industrial and building wiring applications. It is also rated for isolation per both standards."},{"question":"Where can I buy A9F06263?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}