{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06416","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06416","canonicalUrl":"https://aoctrl.com/schneider/A9F06416","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06416","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, A9F06416, miniature circuit breaker, 4P, 16 A rated, B-curve, 42 kA breaking capacity at 133 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F06416 is an Acti9 iC60H miniature circuit breaker — 4 poles, 16 A rated current, B-curve trip characteristic. Breaking capacity hits 42 kA Icu at 12–133 V AC, 30 kA at 220–240 V, 15 kA at 380–415 V, and 10 kA at 440 V — that's a high-interrupting frame for a 16 A MCB, meaning it can ride through a stiff fault on a large transformer without welding its contacts shut. The 10 kA Icn at 400 V per EN/IEC 60898-1 covers the standard domestic/commercial panel fault level. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar), which gives it a foot in both worlds: the 60947-2 listing carries the higher Icu ratings and isolation suitability, while the 60898-1 listing gives the standard Icn for branch-circuit protection. IP20 finger-safe front, so it's panel-mount only — no washdown rating. Carries the usual Schneider declaration of performance and CE marking per the Low Voltage Directive.","metaTitle":"Schneider Electric A9F06416 Acti9 iC60H MCB, 16A Curve B 4P","metaDescription":"Schneider Electric A9F06416 Acti9 iC60H miniature circuit breaker, 16 A rated, B-curve, 4-pole. Breaking capacity 42 kA at 133 V AC. Current lifecycle stage. Sourced to order again","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f1f7be97f3195dda9b3ddc4259f70663.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06416/miniature-circuit-breaker-mcb-acti9-ic60h-4p-16a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06416/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F06416 at 400 V?","answer":"At 400 V AC, the A9F06416 carries a 15 kA Icu per EN/IEC 60947-2 and a 10 kA Icn per EN/IEC 60898-1."},{"question":"What is the closest alternative to the A9F06416 in the Acti9 family?","answer":"The standard iC60 (without the H suffix) is the same physical footprint and rating but with lower breaking capacity — typically 6 kA or 10 kA Icn instead of the 10–42 kA range on the iC60H. If your panel fault current is under 10 kA, the standard iC60 saves cost; if you need the higher interrupt rating, stick with the A9F06416."},{"question":"Where can I buy the A9F06416?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06416","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06416 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}