{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06610","canonicalUrl":"https://aoctrl.com/schneider/A9F06610","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit breaker, A9F06610, B curve, 10 A, 1P+N, 42 kA Icu at 12-60 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F06610 is an Acti9 iC60H miniature circuit breaker with a B curve, rated 10 A, 1P+N, and a breaking capacity of 42 kA Icu at 12-60 V AC. The thermal-magnetic trip unit provides overcurrent and short-circuit protection, with magnetic tripping at 4 x In +/- 20 %. The B curve (magnetic trip at 4 x In) means this MCB is suited for resistive or general-purpose loads with low inrush — common in lighting, socket circuits, and control transformers. The 10 A rating handles branch circuits up to that continuous current. The 42 kA Icu at 12-60 V AC is the ultimate breaking capacity under EN/IEC 60947-2; at 230 V AC the Icn under EN/IEC 60898-1 is 10000 A. The 1P+N configuration switches the phase and provides a switched neutral, with the neutral on the left side.","metaTitle":"A9F06610 Acti9 iC60H MCB, B Curve 10 A, 1P+N, 42 kA","metaDescription":"Schneider Electric A9F06610 Acti9 iC60H miniature circuit breaker, B curve, 10 A, 1P+N, 42 kA Icu at 12-60 V AC. Current lifecycle. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bff409391603dedd998d8037d7e3ffd6.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06610/miniature-circuit-breaker-mcb-acti9-ic60h-1p+n-10a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06610/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F06610?","answer":"The breaking capacity is 42 kA Icu at 12-60 V AC (EN/IEC 60947-2), 30 kA Icu at 100-133 V AC, 15 kA Icu at 220-240 V AC, and 10000 A Icn at 230 V AC (EN/IEC 60898-1)."},{"question":"What standards does A9F06610 comply with?","answer":"It complies with EN/IEC 60947-2 and EN/IEC 60898-1, and is suitable for isolation per both standards. Pollution degree 3, overvoltage category IV."},{"question":"Where can I buy A9F06610?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}