{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06616","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06616","canonicalUrl":"https://aoctrl.com/schneider/A9F06616","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06616","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit breaker, A9F06616, 16 A rated current, 1P+N, curve B, 42 kA breaking capacity at 12-60 V AC, DIN rail mount, IP20.","salesMarkdown":"The Schneider Electric A9F06616 is a miniature circuit breaker from the Acti9 iC60H series, rated 16 A, 1P+N, with a B tripping curve. It is a thermal-magnetic MCB designed for distribution in final subcircuits. The B curve means magnetic tripping occurs between 3.2 and 4.8 times rated current (4 x In +/- 20 %) — suited for resistive or general-purpose loads where inrush is low. It carries a 42 kA breaking capacity at 12-60 V AC, which is the Icu per IEC 60947-2; the Icn per IEC 60898-1 is 10 kA at 230 V AC. That dual rating tells you this breaker is certified to both standards — it can be specified in industrial panels (60947-2) or residential/commercial distribution boards (60898-1). The 1P+N configuration switches the phase and provides a switched neutral on the left side. Mounts on DIN rail, occupies 4 x 9 mm pitches — that is 36 mm width, 91 mm height, 78.5 mm depth. IP20 finger-safe terminals — fine for enclosed panels; not for washdown zones. Overvoltage category IV — rated for the main distribution board, not just sub-distribution. Suitability for isolation is confirmed under both standards. Separate earth-leakage protection block can be added. Contact position indicator and trip indicator give clear visual status.","metaTitle":"Schneider Electric A9F06616 Acti9 iC60H MCB, 16 A, 1P+N, Cur","metaDescription":"Schneider Electric A9F06616 Acti9 iC60H miniature circuit breaker, 16 A rated current, 1P+N, curve B, 42 kA breaking capacity at 12-60 V AC, DIN rail mount. Sourced to order agains","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/daa8882f7616f27f4e05764632cefe16.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06616/miniature-circuit-breaker-mcb-acti9-ic60h-1p+n-16a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06616/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9F06616?","answer":"Submit an RFQ for the A9F06616. We source it to order through independent distribution; availability and current pricing are confirmed at quote time. No stock count or lead-time number is published here."},{"question":"What is A9F06616's breaking capacity?","answer":"The A9F06616 has a 42 kA Icu at 12-60 V AC per IEC 60947-2, and a 10 kA Icn at 230 V AC per IEC 60898-1."},{"question":"What is the closest alternative to A9F06616 in the same family?","answer":"Within the Acti9 iC60 range, the main variant is the curve choice: the A9F06616 is curve B. For the same 16 A, 1P+N rating, a curve C version (e.g., A9F07616) would trip magnetically at 5-10 x In instead of 3.2-4.8 x In — use curve C for moderate inrush loads like small motors or transformers. The footprint and breaking capacity are identical."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06616","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06616 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}