{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F06650","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F06650","canonicalUrl":"https://aoctrl.com/schneider/A9F06650","factsUrl":"https://aoctrl.com/api/mcp/products/A9F06650","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit-breaker, 50 A, 1P+N, curve B, 42 kA breaking capacity at 12-60 V AC, thermal-magnetic trip, DIN rail mount.","salesMarkdown":"## Acti9 iC60H at a glance It is a 1P+N unit — one protected pole plus a switched neutral — and carries a 42 kA breaking capacity (Icu) at 12-60 V AC, which drops to 15 kA at 220-240 V AC per EN/IEC 60947-2. The thermal-magnetic trip unit gives you two layers of protection: a thermal bimetal for sustained overloads (heating up over time) and a magnetic coil for instantaneous short-circuit trips. The B-curve magnetic trip threshold is 4 x In ±20 %, so for a 50 A breaker the magnetic pickup sits between roughly 160 A and 240 A — fast enough to clear a hard short but tolerant of mild inrush from resistive loads. This makes it a distribution-grade MCB (Category A per EN/IEC 60947-2), not a motor-protection device. It is dual-rated to both EN/IEC 60898-1 (household-style MCB standard) and EN/IEC 60947-2 (industrial circuit-breaker standard), so it can be specified in residential consumer units or industrial panelboards. The 10,000 A Icn at 230 V AC under the 60898-1 standard is the domestic rating; the higher 60947-2 Icu figures apply when it is installed in an industrial enclosure with proper coordination. You get isolation capability certified under both standards, which means it can be used as a disconnecting means for downstream circuits. Snaps onto a standard 35 mm DIN rail — 4 module pitches wide (36 mm per pole, so 4 x 9 mm = 36 mm total width). Height is 91 mm, depth 78.5 mm. Terminals accept double conductors: 1-35 mm² rigid or 1-25 mm² flexible, with a stripping length of 14 mm and a tightening torque of 3.5 N.m. The toggle control has a trip indicator window that shows green/red for contact position, so you can visually confirm the state without removing the cover.","metaTitle":"Schneider Electric A9F06650 Acti9 iC60H MCB, 50 A, 1P+N, Cur","metaDescription":"Schneider Electric A9F06650 Acti9 iC60H miniature circuit breaker, 50 A rated, 1P+N, curve B, 42 kA breaking capacity at 12-60 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"50 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e50f82932efc4b957cb2fe629035858a.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F06650/miniature-circuit-breaker-mcb-acti9-ic60h-1p+n-50a-b-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F06650/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F06650?","answer":"The A9F06650 has a 42 kA Icu at 12-60 V AC and 15 kA Icu at 220-240 V AC per EN/IEC 60947-2, plus a 10,000 A Icn at 230 V AC per EN/IEC 60898-1."},{"question":"What is the depth of the A9F06650?","answer":"The A9F06650 has a depth of 78.5 mm, a width of 36 mm (4 module pitches), and a height of 91 mm."},{"question":"What standards does the A9F06650 comply with?","answer":"It is dual-certified to EN/IEC 60947-2 and EN/IEC 60898-1, with isolation capability confirmed under both standards. Pollution degree 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F06650","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F06650 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}