{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07213","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07213","canonicalUrl":"https://aoctrl.com/schneider/A9F07213","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07213","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F07213, 13 A, 2P, C-curve, 42 kA breaking capacity at 12-133 V AC, DIN rail mount, IP20.","salesMarkdown":"## 13 A, 2-pole C-curve MCB for distribution boards The Schneider Electric A9F07213 is an Acti9 iC60H miniature circuit breaker rated at 13 A with a C-curve trip characteristic, covering 2 protected poles in a 36 mm wide DIN-rail housing. The thermal-magnetic trip unit gives you both overload protection (bimetal strip) and short-circuit protection (solenoid) in one package. Breaking capacity is the headline here: 42 kA Icu at 12-133 V AC, 30 kA at 220-240 V AC, 15 kA at 380-415 V AC, and 10 kA at 440 V AC per EN/IEC 60947-2. That puts it in the high-breaking-capacity class (iC60H) — suitable for installation close to the transformer or in high-fault-current panels where standard 6 kA or 10 kA MCBs would need upstream fusing or a current-limiting breaker. The 15 kA Icn at 400 V per EN/IEC 60898-1 confirms it meets the domestic/commercial standard as well. ## Dual standard certification and isolation suitability This breaker carries dual certification to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial), which means it can be specified for either a panelboard in a factory or a distribution board in a building without swapping part numbers. The IP20 finger-safe front keeps live terminals out of reach on the panel face. The toggle control gives a clear visual indication of the contact position, and the trip indicator shows when the breaker has tripped on fault — useful for troubleshooting without removing the panel cover.","metaTitle":"Schneider Electric A9F07213 Acti9 iC60H MCB, 13 A, 2P, C-Cur","metaDescription":"Schneider Electric A9F07213 Acti9 iC60H miniature circuit breaker, 13 A rated current, 2-pole, C-curve, 42 kA breaking capacity at 12-133 V AC. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f865c7b13675c0ffcbb96106cde7381a.pdf","sourceUrl":"https://www.se.com/mk/en/product/A9F07213/miniature-circuit-breaker-mcb-acti9-ic60h-2p-13a-c-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07213/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F07213 at 400 V?","answer":"At 380-415 V AC the breaking capacity is 15 kA Icu per EN/IEC 60947-2, and at 400 V it is rated 15 kA Icn per EN/IEC 60898-1."},{"question":"What is the closest alternative to the A9F07213 in the Acti9 range?","answer":"Within the Acti9 iC60H family, the closest peer is the same 2-pole C-curve breaker at a different current rating — the A9F07213 is the 13 A variant. No pin-compatible direct substitute exists at a different current; select the rating that matches the load."},{"question":"Where can I buy the A9F07213?","answer":"The A9F07213 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for the A9F07213?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries an IP20 rating per IEC 60529 and tropicalisation class 2 per IEC 60068-1. RoHS and REACH declarations are standard for the Acti9 range."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07213","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07213 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}