{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07232","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07232","canonicalUrl":"https://aoctrl.com/schneider/A9F07232","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07232","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, 32 A, C-curve, 2 poles, breaking capacity 42 kA Icu at 12-133 V AC, DIN rail mount.","salesMarkdown":"The C-curve (magnetic tripping at 8 x In ±20 %) means it handles moderate inrush — typical for lighting, socket circuits, and small motor loads — without nuisance trips. The 42 kA Icu at 12-133 V AC (EN/IEC 60947-2) is the maximum fault current it can safely interrupt; at 380-415 V AC that drops to 15 kA Icu, and under the domestic standard (EN/IEC 60898-1) the Icn is 10 kA at 400 V AC. For a distribution board feeding mixed loads, this breaker covers both the higher SCCR needed at low voltage and the standard 10 kA domestic rating. ## Deployment context Snaps onto DIN rail (mounting support: DIN rail per). Terminals accept 1-35 mm² rigid or 1-25 mm² flexible, double terminal top and bottom — useful for daisy-chaining or paralleling feeds. IP20 finger-safe protection; suitable for dry indoor panels only, not washdown areas.","metaTitle":"Schneider Electric A9F07232 Acti9 iC60H MCB, 32 A, C-curve,","metaDescription":"Schneider Electric A9F07232 Acti9 iC60H miniature circuit breaker, 32 A rated current, C-curve, 2 poles, 42 kA Icu breaking capacity, DIN rail mount, current production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ecc66b7274fa1f869abc3bf92aaa923b.pdf","sourceUrl":"https://www.se.com/mk/en/product/A9F07232/miniature-circuit-breaker-mcb-acti9-ic60h-2p-32a-c-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07232/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F07232?","answer":"The breaking capacity varies by voltage: 42 kA Icu at 12-133 V AC, 30 kA Icu at 220-240 V AC, 15 kA Icu at 380-415 V AC, and 10 kA Icu at 440 V AC per EN/IEC 60947-2; under EN/IEC 60898-1 the Icn is 10 kA at 400 V AC."},{"question":"Where can I buy A9F07232?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm offer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07232","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07232 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}