{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07270","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07270","canonicalUrl":"https://aoctrl.com/schneider/A9F07270","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07270","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit breaker, A9F07270, 0.5 A rated current, C curve, 2 poles, 70 kA Icu at 240 V AC, DIN rail mount.","salesMarkdown":"Schneider Electric A9F07270 is an Acti9 iC60H miniature circuit breaker rated at 0.5 A, C curve, 2 poles, with 70 kA Icu at 220...240 V AC. At 380-415 V it holds 70 kA, at 440 V it derates to 50 kA. IEC 60898-1 rating gives 15 kA Icn at 400 V. C curve magnetic trip at 8 x In (±20%) means it trips instantaneously between 3.2 and 4.8 A — suited for resistive and general loads, not high-inrush motor circuits. Utilisation category A (EN/IEC 60947-2) confirms it's not intended for motor starting duty under short-circuit conditions. ## Panel integration and termination Mounts on DIN rail, 36 mm width (4 x 9 mm pitches), 91 mm height, 78.5 mm depth. Tightening torque 2 N.m, strip length 14 mm. IP20 finger-safe front, pollution degree 3, overvoltage category IV — suitable for main distribution boards, not wet environments. Earth-leakage protection requires a separate Vigi iC60 block (not included) — the MCB itself provides overcurrent and short-circuit only. Trip indicator and contact position indicator give visual confirmation of state without opening the door. Suitability for isolation marked yes to both standards — it can be used as a disconnecting means with visible gap confirmation.","metaTitle":"Schneider A9F07270 Acti9 iC60H MCB, 0.5 A, C Curve, 2P, 70 k","metaDescription":"Schneider Electric A9F07270 Acti9 iC60H miniature circuit breaker, 0.5 A rated current, C curve, 2 poles, 70 kA breaking capacity at 240 V AC. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"0.5 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/356900a9568c1a81c71143e4b5462725.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F07270/miniature-circuit-breaker-mcb-acti9-ic60h-2p-0-5a-c-curve-10000a-iec-608981-70ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07270/alternatives.json"},"ai":{"faq":[{"question":"What is A9F07270's breaking capacity at 240 V?","answer":"70 kA Icu at 220...240 V AC (EN/IEC 60947-2) and 15 kA Icn at 400 V (EN/IEC 60898-1). At 440 V it holds 50 kA Icu."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07270","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07270 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}