{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07413","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07413","canonicalUrl":"https://aoctrl.com/schneider/A9F07413","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07413","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F07413, 4 poles, C-curve, 13 A rated current, 42 kA Icu breaking capacity at 133 V AC, dual-standard EN/IEC 60947-2 and EN/IEC 60898-1.","salesMarkdown":"The Schneider Electric A9F07413 is a 4-pole miniature circuit-breaker from the Acti9 iC60H series, rated 13 A with a C-curve trip characteristic. It is dual-rated to both EN/IEC 60947-2 and EN/IEC 60898-1, meaning it carries the higher breaking capacity of an industrial breaker (42 kA Icu at 12...133 V AC) while also meeting the residential/commercial MCB standard. That dual rating is the key spec for a buyer: it lets you use this one part number for distribution panels where you need the SCCR headroom of a 60947-2 device, not just a 60898-1 domestic MCB. The 42 kA Icu at 133 V AC is the headline figure, but the real-world selectivity picture depends on the voltage on your bus. At 220...240 V AC the Icu drops to 30 kA; at 380...415 V AC it's 15 kA; at 440 V AC it's 10 kA. Under the 60898-1 standard the Icn is 15 kA at 400 V AC. For a 400 V distribution panel, the 15 kA Icu at 415 V is what governs your upstream breaker coordination — that's the figure to plug into your selectivity study, not the 42 kA number. Height is 91 mm, depth 78.5 mm. The double terminal accepts 1...25 mm² rigid or 1...16 mm² flexible wire; strip length 14 mm, tighten to 2 N.m. IP20 finger-safe front, pollution degree 3 rated, overvoltage category IV. That's a standard panel footprint — no surprises for a panel builder laying out a 4-pole MCB in a distribution board.","metaTitle":"Schneider Electric A9F07413 Acti9 iC60H MCB, 4P C-curve 13 A","metaDescription":"Schneider Electric A9F07413 Acti9 iC60H miniature circuit-breaker. 4 poles, C-curve, 13 A rated current. Breaking capacity 42 kA Icu at 133 V AC. Dual-rated to EN/IEC 60947-2 and 6","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4d49fe704b9aa32a7d9c77463332968.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F07413/miniature-circuit-breaker-mcb-acti9-ic60h-4p-13a-c-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07413/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F07413 at 400 V?","answer":"At 380...415 V AC the Icu is 15 kA per EN/IEC 60947-2; under EN/IEC 60898-1 the Icn is 15 kA at 400 V AC."},{"question":"What is the closest alternative to A9F07413 in the Acti9 family?","answer":"Within the same Acti9 iC60H series, the closest peer would be a 4-pole C-curve MCB at a different current rating — the mechanical footprint, breaking capacity, and terminal specs are identical; only the thermal trip element changes. No pin-compatible alternative exists outside the iC60 family without re-verifying the DIN-rail layout and terminal capacity."},{"question":"How do I get pricing and availability for A9F07413?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment."},{"question":"What compliance documentation does Schneider provide for A9F07413?","answer":"The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1, carries IP20 per IEC 60529, and is tropicalised to class 2 per IEC 60068-1. Standard Schneider declarations of conformity and the product datasheet cover RoHS and REACH compliance — available on request with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07413","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07413 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}