{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07432","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07432","canonicalUrl":"https://aoctrl.com/schneider/A9F07432","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07432","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, A9F07432, miniature circuit breaker, 4P, 32 A, C-curve, 15 kA Icn at 400 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F07432 is an Acti9 iC60H miniature circuit breaker (MCB) rated 32 A with a C-curve magnetic trip at 8 x In ±20 % — meaning it holds through moderate inrush (motor start, capacitor bank) and trips fast on a hard short. Four poles (4P) switch all live conductors, so it suits three-phase plus neutral distribution in a panel. The 15 kA Icn at 400 V AC (EN/IEC 60898-1) and 15 kA Icu at 380–415 V AC (EN/IEC 60947-2) tell you it safely interrupts fault currents up to that level without welding contacts or cascading upstream — sized for commercial and light industrial sub-distribution boards where the prospective short-circuit current is known. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit — no electronic auxiliary power needed, which keeps the trip curve stable across temperature swings inside a warm enclosure. Snaps onto a DIN rail (mounting support per). The 72 mm width (9 mm pitches × 8) means it occupies eight modular spaces in a distribution board — plan the rail layout accordingly. Double terminals top and bottom accept 1–35 mm² rigid or 1–25 mm² flexible; strip length 14 mm, tighten to 3.5 N·m. The toggle control provides local on/off switching with a trip indicator (red flag) that shows when the breaker has opened on fault — useful for a technician scanning a row of MCBs to find the tripped circuit without metering each one. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar) — the same breaker covers both installation standards, which simplifies procurement when a panel must meet both a local residential code and an industrial machinery directive.","metaTitle":"Schneider Electric A9F07432 Acti9 iC60H MCB, 32 A, 4P, C-Cur","metaDescription":"Schneider Electric A9F07432 Acti9 iC60H miniature circuit breaker, 32 A rated, 4 poles, C-curve, 15 kA at 400 V AC. Active production, sourced to order. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3566116ac6ef5715eab11496ef176c6e.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F07432/miniature-circuit-breaker-mcb-acti9-ic60h-4p-32a-c-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07432/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F07432 and how do I get a price?","answer":"The A9F07432 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm landed-cost number."},{"question":"What is A9F07432's breaking capacity at 400 V?","answer":"The A9F07432 has a 15 kA Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1, and a 15 kA Icu at 380–415 V AC conforming to EN/IEC 60947-2."},{"question":"What compliance documentation does Schneider Electric provide for A9F07432?","answer":"The A9F07432 is certified to EN/IEC 60947-2 and EN/IEC 60898-1, rated for pollution degree 3, tropicalisation class 2 per IEC 60068-1, and overvoltage category IV. Standard Schneider Electric declarations of conformity and CE/UKCA marking apply."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07432","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07432 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}