{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07463","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07463","canonicalUrl":"https://aoctrl.com/schneider/A9F07463","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07463","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, A9F07463, miniature circuit breaker, 63 A, 4P, C-curve, 42 kA breaking capacity, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F07463 is an Acti9 iC60H miniature circuit breaker rated 63 A with a C-curve trip characteristic, 4 protected poles, and a 42 kA ultimate breaking capacity (Icu) at 12–133 V AC. The 63 A C-curve means the magnetic trip activates at 8 x In ±20 % — roughly 504 A instantaneous — which suits moderate inrush loads like lighting banks, small motor groups, or transformer primaries without nuisance tripping. The 42 kA Icu at low voltage drops to 30 kA at 220–240 V and 15 kA at 380–415 V; that 15 kA at 400 V is the figure to coordinate with downstream branch breakers in a typical European distribution board. Overvoltage category IV and pollution degree 3 mean this breaker is rated for the main incoming supply at the service entrance — not just sub-distribution — in environments with conductive dust or humidity. ## Panel integration IP20 finger-safe terminals are standard for enclosed panels.","metaTitle":"Schneider Electric A9F07463 Acti9 iC60H MCB, 63 A, 4P, C-Cur","metaDescription":"Schneider Electric A9F07463 Acti9 iC60H miniature circuit breaker, 63 A rated, 4 poles, C-curve, 42 kA breaking capacity. Dual-certified EN/IEC 60947-2 and 60898-1. Active producti","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b8aedeaa7b3ce1b3d925df5b3a781e38.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F07463/miniature-circuit-breaker-mcb-acti9-ic60h-4p-63a-c-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07463/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F07463 and how do I get a price?","answer":"The A9F07463 is sourced and quoted to order through independent distribution against an RFQ. Submit a request for quote (RFQ) to confirm current availability and pricing — no stock count or price figure is published here."},{"question":"What is A9F07463's listed depth?","answer":"The depth is 78.5 mm, which fits standard DIN-rail enclosures with a 100 mm minimum internal depth."},{"question":"What compliance documentation does Schneider provide for A9F07463?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, and carries tropicalisation class 2 per IEC 60068-1. RoHS and REACH declarations are standard for the Acti9 range; consult the product documentation for specific certificates."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07463","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07463 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}