{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07470","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07470","canonicalUrl":"https://aoctrl.com/schneider/A9F07470","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07470","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, A9F07470, miniature circuit breaker, 4P, 0.5 A rated current, C-curve, 70 kA breaking capacity, DIN rail mount, white.","salesMarkdown":"## Breaking capacity and dual-standard certification The Schneider Electric A9F07470 is an Acti9 iC60H miniature circuit breaker rated 0.5 A, 4-pole, with a C-curve magnetic trip at 8 x In ±20 %. Its headline figure is the 70 kA breaking capacity (Icu) at 220…240 V AC and 380…415 V AC per EN/IEC 60947-2, dropping to 50 kA at 440 V AC and 15 kA Icn at 400 V per EN/IEC 60898-1. That 70 kA rating means it clears high-fault currents typical of industrial distribution panels without upstream cascading — the SCCR headroom is real for a 0.5 A device. Dual-certified to EN/IEC 60898-1 (household / commercial) and EN/IEC 60947-2 (industrial). The 60947-2 certification gives you Category A utilization (no intentional short-time delay) and pollution degree 3 — meaning it's rated for the conductive dust and humidity you'd see in a factory floor panel, not just a clean office board. Overvoltage category IV suits main-distribution-board installation. The C-curve (8 x In magnetic trip) is standard for moderate inrush loads — think small contactor coils, control transformers, or lighting banks. At 0.5 A, this is sized for a control-circuit feeder, not a motor branch. ## Panel integration and lifecycle Mounts on standard DIN rail (9 mm pitch, 8 modules wide). Terminals accept 1…25 mm² rigid or 1…16 mm² flexible on double terminals top and bottom — torque to 2 N·m. The white housing and trip-indicator flag give clear visual status.","metaTitle":"Schneider Electric A9F07470 Acti9 iC60H MCB, 4P, 0.5 A, C-Cu","metaDescription":"Schneider Electric A9F07470 Acti9 iC60H miniature circuit breaker, 4P, 0.5 A, C-curve, 70 kA breaking capacity. Sourced to order against RFQ. Dual-certified EN/IEC 60898-1 and 6094","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"0.5 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4f53877491e910e3a263278fe96f7dd2.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F07470/miniature-circuit-breaker-mcb-acti9-ic60h-4p-0-5a-c-curve-10000a-iec-608981-70ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07470/alternatives.json"},"ai":{"faq":[{"question":"What is A9F07470's breaking capacity?","answer":"70 kA Icu at 220…240 V AC and 380…415 V AC per EN/IEC 60947-2, 50 kA at 440 V AC, and 15 kA Icn at 400 V per EN/IEC 60898-1."},{"question":"Where can I buy A9F07470?","answer":"The A9F07470 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does A9F07470 carry?","answer":"The breaker is certified to EN/IEC 60898-1 and EN/IEC 60947-2, with a pollution degree of 3, overvoltage category IV, and tropicalisation class 2 per IEC 60068-1. It is suitable for isolation per both standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07470","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07470 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}