{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07632","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07632","canonicalUrl":"https://aoctrl.com/schneider/A9F07632","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07632","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, A9F07632, miniature circuit breaker, 1P+N, 32 A, C curve, 42 kA Icu at 12-60 V AC, thermal-magnetic, DIN rail.","salesMarkdown":"The A9F07632 is a Schneider Electric Acti9 iC60H miniature circuit breaker (MCB) rated 32 A with a C curve — magnetic tripping at 8 x In (±20 %), so it handles moderate inrush from motor starters and lighting ballasts without nuisance trips. Breaking capacity reaches 42 kA Icu at 12-60 V AC (EN/IEC 60947-2), dropping to 15 kA at 220-240 V AC, and 10 kA Icn at 230 V AC (EN/IEC 60898-1) — the higher Icu figure governs industrial panel coordination; the Icn figure is the residential/commercial rating. Dual-certified to both the industrial (60947-2) and household (60898-1) standards, so it qualifies for distribution boards and sub-distribution in the same enclosure. IP20 finger-safe front, suitable for enclosed distribution boards. Pollution degree 3 (conductive pollution) per EN/IEC 60947-2 — expect it in industrial environments where occasional condensation or light dust is present.","metaTitle":"Schneider Electric A9F07632 Acti9 iC60H MCB, 32 A, C Curve,","metaDescription":"Schneider Electric A9F07632 Acti9 iC60H miniature circuit breaker, 32 A rated current, C curve, 1P+N, 42 kA breaking capacity at 12-60 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a1526f7fbca08489d7810b477c8c3c08.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F07632/miniature-circuit-breaker-mcb-acti9-ic60h-1p+n-32a-c-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07632/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9F07632 and how is it quoted for volume purchases?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."},{"question":"What is A9F07632's listed depth (78.5 mm) on this component line?","answer":"The A9F07632 has a depth of 78.5 mm, a height of 91 mm, and a width of 36 mm (4 x 9 mm pitches)."},{"question":"What is A9F07632's listed range (Acti9) on this component line?","answer":"The A9F07632 belongs to the Schneider Electric Acti9 range, specifically the iC60H device short name within that family."},{"question":"What compliance documentation does this brand provide for A9F07632 (RoHS, REACH, UL, IEC)?","answer":"The A9F07632 is certified to EN/IEC 60947-2 and EN/IEC 60898-1. It carries an IP20 rating per IEC 60529 and tropicalisation class 2 per IEC 60068-1. The evidence does not list RoHS, REACH, or UL documentation specifically for this order code."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07632","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07632 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}