{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F07650","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F07650","canonicalUrl":"https://aoctrl.com/schneider/A9F07650","factsUrl":"https://aoctrl.com/api/mcp/products/A9F07650","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit-breaker, A9F07650, 50 A rated, C-curve, 1P+N, 15 kA Icu at 240 V AC, DIN rail mount.","salesMarkdown":"The A9F07650 is a Schneider Electric Acti9 iC60H miniature circuit-breaker (MCB) rated at 50 A with a C-curve magnetic trip at 8 x In ±20%, meaning it handles moderate inrush from motor starters or lighting ballasts without nuisance tripping. The 1P+N configuration switches the phase and provides a switched neutral, common in single-phase distribution boards where neutral isolation is required. Breaking capacity is 15 kA Icu at 220–240 V AC per EN/IEC 60947-2, and 10 kA Icn at 230 V per EN/IEC 60898-1 — the higher Icu figure governs fault clearance in industrial panels where upstream transformers can deliver substantial short-circuit current. The double terminal accepts 1–35 mm² rigid or 1–25 mm² flexible on top or bottom, with a tightening torque of 3.5 N·m and a wire stripping length of 14 mm. The neutral position is left, and the toggle control includes a trip indicator and contact position indicator for visual status.","metaTitle":"Schneider Electric A9F07650 Acti9 iC60H MCB, 50 A, C-curve,","metaDescription":"Schneider Electric A9F07650 Acti9 iC60H miniature circuit-breaker, 50 A rated, C-curve, 1P+N, 15 kA Icu at 240 V AC, DIN rail. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P + N","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"50 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c96e4c05c3889a144f9e167a4b5fc6f.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F07650/miniature-circuit-breaker-mcb-acti9-ic60h-1p+n-50a-c-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F07650/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of A9F07650?","answer":"Rated current 50 A, C-curve, 1P+N poles, breaking capacity 15 kA Icu at 220–240 V AC per EN/IEC 60947-2 and 10 kA Icn at 230 V per EN/IEC 60898-1, thermal-magnetic trip, DIN rail mount, IP20."},{"question":"Where can I buy A9F07650?","answer":"The A9F07650 is sourced and quoted to order against an RFQ through independent distribution channels; availability and current pricing are confirmed at quote time."},{"question":"What compliance standards does A9F07650 meet?","answer":"It conforms to EN/IEC 60947-2 and EN/IEC 60898-1, with tropicalisation class 2 per IEC 60068-1 and pollution degree 3 per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F07650","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F07650 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}