{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F08150","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F08150","canonicalUrl":"https://aoctrl.com/schneider/A9F08150","factsUrl":"https://aoctrl.com/api/mcp/products/A9F08150","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, 1P, D-curve, 50 A, 15 kA Icn at 230 V AC, miniature circuit breaker.","salesMarkdown":"The Schneider Electric A9F08150 is a 1-pole Acti9 iC60H miniature circuit breaker with a D tripping curve and a 50 A rated current. It's built for distribution boards and sub-panels where high inrush loads — motor starting, transformer energisation, or capacitive banks — demand a magnetic trip threshold of 12 x In (±20 %) to avoid nuisance tripping. The thermal-magnetic trip unit handles the overload side; the magnetic element clears short-circuits fast. For industrial duty, the Icu per EN/IEC 60947-2 is 42 kA at 12–60 V AC, 30 kA at 100–133 V AC, and 15 kA at 220–240 V AC. On DC: 20 kA at 12–60 V DC, 15 kA at 60–72 V DC. The D curve's 12 x In magnetic trip ensures it won't drop out on motor start current, but still trips fast on a hard short. Snaps onto a standard 35 mm DIN rail (EN 60715) and occupies 2 x 9 mm pitches (18 mm wide). Height is 91 mm, depth 78.5 mm — fits most distribution enclosures. Strip length 14 mm. IP20 rated — suitable for dry indoor panels only.","metaTitle":"A9F08150 Acti9 iC60H MCB, 1P D 50 A, 15 kA Icn","metaDescription":"Schneider Electric A9F08150 Acti9 iC60H miniature circuit breaker, 1-pole D-curve 50 A, 15 kA Icn at 230 V AC. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"50 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 20 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 15 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e9f0880862b8105d84c905994425480b.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F08150/miniature-circuit-breaker-mcb-acti9-ic60h-1p-50a-d-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F08150/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F08150?","answer":"The A9F08150 has a 15 kA Icn at 230 V AC per EN/IEC 60898-1, and an Icu of 42 kA at 12–60 V AC, 30 kA at 100–133 V AC, and 15 kA at 220–240 V AC per EN/IEC 60947-2."},{"question":"What does the D curve mean on the A9F08150?","answer":"The D curve means the magnetic trip threshold is 12 x In (±20 %), designed for loads with high inrush current like motors, transformers, and discharge lamps."},{"question":"Where can I buy the A9F08150?","answer":"The A9F08150 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F08150","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F08150 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}