{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F08163","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F08163","canonicalUrl":"https://aoctrl.com/schneider/A9F08163","factsUrl":"https://aoctrl.com/api/mcp/products/A9F08163","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit-breaker, 1P, 63 A, curve D, 42 kA Icu at 12-60 V AC, 78.5 mm depth, 18 mm width, IP20.","salesMarkdown":"The A9F08163 is a 1-pole Acti9 iC60H miniature circuit-breaker rated 63 A with a D tripping curve. The 42 kA Icu at 12-60 V AC (per EN/IEC 60947-2) tells you it can safely interrupt a fault up to that level without upstream cascading; at 230 V AC the Icn is 10 kA per EN/IEC 60898-1, which is the domestic/light-commercial standard. Mounts on DIN rail (EN 60715). The toggle and trip indicator are visible through the panel door. Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic). Pollution degree 3, overvoltage category IV. Suitability for isolation is confirmed under both standards. No earth-leakage protection built in — that is handled separately by a residual-current device upstream.","metaTitle":"A9F08163 Acti9 iC60H MCB, 63 A, 1P, Curve D, 42 kA","metaDescription":"Schneider Electric A9F08163 Acti9 iC60H miniature circuit-breaker, 63 A, 1P, curve D, 42 kA Icu at 12-60 V AC. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","[In] rated current":"63 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...35 mm² rigid Double terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60947-2 Yes conforming to EN/IEC 60898-1","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 20 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 15 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/12684966422d06aa6db15f0574210d71.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F08163/miniature-circuit-breaker-mcb-acti9-ic60h-1p-63a-d-curve-10000a-iec-608981-15ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F08163/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F08163?","answer":"The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9F08163?","answer":"42 kA Icu at 12-60 V AC, 30 kA at 100-133 V AC, 15 kA at 220-240 V AC per EN/IEC 60947-2; 10 kA Icn at 230 V AC per EN/IEC 60898-1."},{"question":"What compliance documentation does Schneider provide for A9F08163?","answer":"The part is certified to EN/IEC 60947-2 and EN/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1. RoHS/REACH declarations are available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F08163","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F08163 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}