{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F08170","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F08170","canonicalUrl":"https://aoctrl.com/schneider/A9F08170","factsUrl":"https://aoctrl.com/api/mcp/products/A9F08170","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, 1P, 0.5 A, D curve, 70 kA Icu at 240 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F08170 is a 1-pole Acti9 iC60H miniature circuit breaker rated at 0.5 A with a D tripping curve. The 70 kA Icu at 220…240 V AC (per EN/IEC 60947-2) gives real fault-current headroom in a panel fed by a large transformer, and the 10 kA Icn at 230 V AC (per EN/IEC 60898-1) covers the residential and light commercial coordination requirement. The iC60H carries a 70 kA Icu rating at 240 V AC under EN/IEC 60947-2, which is the industrial standard for panelboards and motor control centers. For downstream coordination, the limitation class is 3 per EN/IEC 60898-1, so it restricts let-through energy enough to allow standard downstream MCBs to hold their selectivity under most fault conditions. The 20 kA Icu at 12…60 V DC and 15 kA Icu at 60…72 V DC cover DC control circuits or battery-backed loads, though the 0.5 A rating limits the practical DC load to signal-level or small relay coils. Mounts on a DIN rail, 18 mm wide (2 modules). The double terminals top and bottom accept 1…25 mm² rigid or 1…16 mm² flexible copper — enough for a 0.5 A circuit's feed and load in standard panel wire. The toggle has a trip-indicator window that shows a red flag when the breaker has tripped on overload or short circuit, which saves a multimeter check during commissioning or troubleshooting. Pollution degree 3 (conforming to EN/IEC 60947-2) means it's rated for the conductive-dust and humidity conditions typical of industrial control panels, not just clean residential switchgear.","metaTitle":"Schneider Electric A9F08170 Acti9 iC60H MCB, 0.5 A, D Curve,","metaDescription":"Schneider Electric A9F08170 Acti9 iC60H miniature circuit breaker, 0.5 A rated current, D curve, 1 pole, 70 kA breaking capacity at 240 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"0.5 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"70 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 20 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 15 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/be074ede9cc1eba15e1476a842ebf43c.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F08170/miniature-circuit-breaker-mcb-acti9-ic60h-1p-0-5a-d-curve-10000a-iec-608981-70ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F08170/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy the A9F08170 and how do I get a price?","answer":"The A9F08170 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the A9F08170's breaking capacity at 240 V AC?","answer":"70 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2, and 10 kA Icn at 230 V AC conforming to EN/IEC 60898-1."},{"question":"What compliance documentation does Schneider provide for the A9F08170?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1, carries a suitability-for-isolation marking per both standards, and is tropicalised per IEC 60068-1 (class 2). Standard Schneider declarations of conformity and CE/UKCA documentation are available."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F08170","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F08170 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}