{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F08201","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F08201","canonicalUrl":"https://aoctrl.com/schneider/A9F08201","factsUrl":"https://aoctrl.com/api/mcp/products/A9F08201","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, D curve, 1 A rated current, 2 poles, 70 kA Icu at 415 V AC, DIN rail mount, IP20.","salesMarkdown":"The Schneider Electric A9F08201 is an Acti9 iC60H miniature circuit breaker with a D tripping curve, rated 1 A, 2 poles, and a 70 kA Icu breaking capacity at 415 V AC. It's a thermal-magnetic MCB for distribution panels, designed to protect branch circuits against overloads and short circuits. Breaking capacity is dual-rated: 70 kA Icu at 415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V AC per EN/IEC 60898-1. Overvoltage category IV means it's suitable for installation at the origin of the installation, before the main distribution board. The 2-pole version (2P) protects both live conductors. The trip indicator and contact position indicator give visual confirmation of state without needing to measure voltage. Mounts on a DIN rail, occupies 4 module pitches (36 mm width). Depth is 78.5 mm, height 91 mm. The double terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; strip length is 14 mm.","metaTitle":"Schneider Electric A9F08201 Acti9 iC60H MCB, D Curve, 1 A, 2","metaDescription":"Schneider Electric A9F08201 Acti9 iC60H miniature circuit breaker, D curve, 1 A, 2 poles, 70 kA Icu at 415 V AC. Active production, sourced to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"1 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/733f6ab9287ec8a5add4933f6ef3c0ce.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F08201/miniature-circuit-breaker-mcb-acti9-ic60h-2p-1a-d-curve-10000a-iec-608981-70ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F08201/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9F08201?","answer":"Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the A9F08201's breaking capacity at 415 V?","answer":"70 kA Icu at 380–415 V AC per EN/IEC 60947-2. At 400 V AC under EN/IEC 60898-1, the Icn is 10 kA."},{"question":"What compliance standards does the A9F08201 meet?","answer":"It conforms to EN/IEC 60947-2 and EN/IEC 60898-1. Tropicalisation class 2 per IEC 60068-1. Pollution degree 3 per EN/IEC 60947-2. Overvoltage category IV."},{"question":"What is the closest alternative to A9F08201 in the Acti9 family?","answer":"Within the Acti9 iC60H range, the main variant difference is the tripping curve (B, C, D) and the rated current. The A9F08201 is the 1 A, D-curve, 2-pole version. A B-curve or C-curve at the same current would trip faster on inrush; a higher current rating (e.g., 2 A or 6 A) would shift the overload threshold. No pin-compatible drop-in exists with a different curve — the trip unit is integral."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F08201","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F08201 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}