{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F08270","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F08270","canonicalUrl":"https://aoctrl.com/schneider/A9F08270","factsUrl":"https://aoctrl.com/api/mcp/products/A9F08270","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08270, 0.5 A rated current, D curve, 2 poles, 70 kA Icu at 415 V AC, DIN rail mount.","salesMarkdown":"## Integrator note: A9F08270 Acti9 iC60H The Schneider Electric A9F08270 is a 2-pole miniature circuit breaker from the Acti9 iC60H series, rated 0.5 A with a D tripping curve. The D curve (magnetic tripping limit 12 x In +/- 20 %) means this breaker tolerates high inrush currents — typical for motor, transformer, or lighting ballast loads — without nuisance tripping. At 0.5 A, it protects a small motor or control transformer circuit where the start-up surge exceeds the C-curve threshold. Breaking capacity is 70 kA Icu at 415 V AC per EN/IEC 60947-2, and 15 kA Icn at 400 V AC per EN/IEC 60898-1. The A9F08270 carries a current lifecycle status from the manufacturer. For audit and tender purposes, the part is listed as suitable for isolation per both standards, and includes a contact position indicator and trip indicator for visual confirmation of status. The DIN-rail mount and 36 mm width (4 modules) fit standard distribution board layouts. Double terminals top and bottom accept 1…25 mm² rigid or 1…16 mm² flexible conductors; strip length 14 mm, tightening torque 2 N.m. IP20 finger-safe protection is maintained when installed in an enclosed panel. Earth-leakage protection requires a separate block (not integrated), so plan for an external RCCB or RCBO if ground-fault protection is needed on the same circuit.","metaTitle":"Schneider Electric A9F08270 Acti9 iC60H MCB, 0.5 A, D Curve,","metaDescription":"Schneider Electric A9F08270 Acti9 iC60H miniature circuit breaker, 0.5 A rated current, D curve, 2 poles, 70 kA breaking capacity at 415 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"0.5 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 125 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/873d448102d674ccd51dddda0010e9e0.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F08270/miniature-circuit-breaker-mcb-acti9-ic60h-2p-0-5a-d-curve-10000a-iec-608981-70ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F08270/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9F08270 at 415 V?","answer":"The A9F08270 has a breaking capacity of 70 kA Icu at 380…415 V AC per EN/IEC 60947-2, and 15 kA Icn at 400 V AC per EN/IEC 60898-1."},{"question":"What is the closest alternative to A9F08270 in the Acti9 range?","answer":"Within the Acti9 iC60H series, the closest alternative would be a different rated current or pole configuration — for example, a 1 A or 1P variant — but the D curve, breaking capacity, and form factor remain identical. No pin-compatible alternative exists outside the series; the iC60H platform is the direct match."},{"question":"Where can I buy A9F08270?","answer":"The A9F08270 is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F08270","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F08270 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}