{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F08301","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F08301","canonicalUrl":"https://aoctrl.com/schneider/A9F08301","factsUrl":"https://aoctrl.com/api/mcp/products/A9F08301","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, miniature circuit breaker, A9F08301, 1 A, D curve, 3P, 70 kA Icu at 415 V AC, DIN rail mount.","salesMarkdown":"The A9F08301: The D curve (magnetic trip at 12 x In ±20 %) means this breaker tolerates high inrush currents — it is sized for motor, transformer, or lighting ballast loads where the start-up surge can hit 10–14 times the running current. At 1 A rated current, it protects a small motor or control transformer branch. The 10 kA Icn at 400 V (EN/IEC 60898-1) is the domestic-grade rating; the higher Icu figure governs in an industrial distribution board where the prospective short-circuit current can exceed 10 kA. Occupies 6 x 9 mm pitches (54 mm wide) on the rail — three poles at 18 mm per pole. Depth is 78.5 mm, height 91 mm. IP20 finger-safe front; the busbar and wiring compartment are protected inside the enclosure. Pollution degree 3 (conductive pollution, e.g. panel dust with condensation) is handled without derating. The A9F08301 is listed as current-production (active lifecycle stage). It is not subject to a phase-out notice or last-time-buy window.","metaTitle":"Schneider Electric A9F08301 Acti9 iC60H MCB, 1 A, D Curve, 3","metaDescription":"Schneider Electric A9F08301 Acti9 iC60H miniature circuit breaker, 1 A rated current, D curve, 3 poles, 70 kA Icu breaking capacity at 415 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC DC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"1 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2463826a81f647da8c39e6191a95bbc2.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F08301/miniature-circuit-breaker-mcb-acti9-ic60h-3p-1a-d-curve-10000a-iec-608981-70ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F08301/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F08301 and get a price?","answer":"The A9F08301 is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm availability and current pricing at the time of order."},{"question":"What is the closest alternative to A9F08301 in the Acti9 family?","answer":"Within the Acti9 iC60 range, the closest peer is the same iC60H platform with a different current rating or curve code. The A9F08301 is a 1 A, D-curve, 3-pole variant; a buyer needing a different rating would select another iC60H order code with the desired In and curve. No direct pin-compatible drop-in from another series is documented."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F08301","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F08301 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}