{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F08302","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F08302","canonicalUrl":"https://aoctrl.com/schneider/A9F08302","factsUrl":"https://aoctrl.com/api/mcp/products/A9F08302","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H, A9F08302, miniature circuit-breaker, D curve, 2 A rated current, 3 poles, 70 kA Icu breaking capacity at 415 V AC, DIN rail mount, thermal-magnetic trip.","salesMarkdown":"The A9F08302 is a Schneider Electric Acti9 iC60H miniature circuit-breaker, a 3-pole unit rated at 2 A with a D tripping curve. The thermal-magnetic trip unit handles the overload side; the magnetic element clears short-circuits. For a 2 A rating, this holds the unit on the grid for steady-state loads up to 2 A and trips fast on a fault, provided the prospective short-circuit current stays within the 70 kA Icu envelope at 415 V. The iC60H designation means this breaker sits in the high-breaking-capacity tier of the Acti9 iC60 family. At 380…415 V AC the Icu is 70 kA; at 440 V it drops to 50 kA, and at 400 V the Icn (service breaking capacity per EN/IEC 60898-1) is 10 kA. For a panel designer coordinating downstream MCBs, the 70 kA Icu figure gives headroom for high-fault installations — large distribution transformers or industrial switchboards — provided the upstream protective device limits let-through energy to what the 2 A D-curve can withstand. The limitation class is 3 per EN/IEC 60898-1, meaning it restricts peak let-through current and I²t, which helps with cascading and reduces arc-flash energy on the load side. Mounts on DIN rail — the 9 mm pitch count is 6, so the breaker occupies 6 modules (54 mm). IP20 finger-safe front. The toggle control has a trip indicator that shows a red flag when the breaker has tripped on fault — useful for a field-service tech walking a panel to find which circuit dropped. Stripping length is 14 mm; torque the terminals to 2 N·m.","metaTitle":"A9F08302 Acti9 iC60H MCB, D Curve 2 A 3P, 70 kA Icu","metaDescription":"Schneider Electric A9F08302 Acti9 iC60H miniature circuit-breaker. D curve, 2 A, 3-pole, 70 kA Icu at 415 V AC. Active production. Sourced to order against RFQ. EN/IEC 60947-2 and","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"91 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"6","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"2 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Double terminal (top or bottom) 1...25 mm² rigid Double terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"70 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 70 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3790362c888742f92021c04603b56bb0.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F08302/miniature-circuit-breaker-mcb-acti9-ic60h-3p-2a-d-curve-10000a-iec-608981-70ka-iec-609472-double-term-/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F08302/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the A9F08302?","answer":"Rated current 2 A, D curve (magnetic trip at 12 x In), 3 poles, breaking capacity 70 kA Icu at 415 V AC per EN/IEC 60947-2, and 10 kA Icn at 400 V AC per EN/IEC 60898-1. Rated insulation voltage 500 V AC."},{"question":"What standards does the A9F08302 comply with?","answer":"Certified to EN/IEC 60947-2 and EN/IEC 60898-1. Suitability for isolation is confirmed per both standards. Pollution degree 3, overvoltage category IV."},{"question":"Where can I buy the A9F08302?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F08302","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F08302 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}