{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F43325","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F43325","canonicalUrl":"https://aoctrl.com/schneider/A9F43325","factsUrl":"https://aoctrl.com/api/mcp/products/A9F43325","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N miniature circuit breaker, A9F43325, 25 A, 3-pole, B-curve, 36 kA breaking capacity, thermal-magnetic trip, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9F43325 is an Acti9 iC60N miniature circuit breaker rated at 25 A with a B-curve trip characteristic, 3 poles, and a thermal-magnetic trip unit. Breaking capacity is the headline differentiator here: 36 kA Icu at 12–133 V AC, 20 kA at 220–240 V, 10 kA at 380–415 V, and 6 kA at 440 V AC per EN/IEC 60947-2. The Icn rating under 60898-1 is 6000 A at 400 V. For DC circuits, it clears 10 kA at 100–133 V DC. The B-curve (4 x In magnetic trip, ±20%) gives it a wider magnetic-trip window than C or D curves, so it tolerates inrush from resistive loads and long cable runs better than a C-curve would. Mounts via clip-on to a DIN rail (35 mm), occupying 6 x 9 mm pitches (54 mm wide). The 78.5 mm depth and 85 mm height fit standard distribution board cutouts. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; torque to 2 N·m. IP20 finger-safe terminals are standard for enclosed panels. A separate earth-leakage block (Vigi iC60) can be added on the right side for RCD protection.","metaTitle":"Schneider Electric A9F43325 iC60N MCB, 25A 3P B-Curve, Acti9","metaDescription":"Schneider Electric A9F43325 iC60N miniature circuit breaker, 25A, 3-pole, B-curve, 36 kA breaking capacity. Acti9 range. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC/DC","Product name":"Disbo iC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"Rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 100...133 V DC conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","[In] rated current":"25 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 180 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - 100...133 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/57d3fc7f18def03ebcb0fa42b1db469e.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F43325/miniature-circuit-breaker-mcb-acti9-ic60n-disbo-3p-25a-b-curve-6000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F43325/alternatives.json"},"ai":{"faq":[{"question":"What is A9F43325's breaking capacity at 415 V?","answer":"At 380–415 V AC, the A9F43325 clears 10 kA Icu per EN/IEC 60947-2. The Icn rating under 60898-1 is 6000 A at 400 V."},{"question":"What compliance standards does the A9F43325 meet?","answer":"It is certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (residential/light commercial). Pollution degree 3, overvoltage category IV, tropicalisation class 2 per IEC 60068-1."},{"question":"Where can I buy the A9F43325?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F43325","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F43325 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}