{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F45425","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F45425","canonicalUrl":"https://aoctrl.com/schneider/A9F45425","factsUrl":"https://aoctrl.com/api/mcp/products/A9F45425","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit-breaker, A9F45425, 4P, 25 A, D curve, 36 kA breaking capacity, clip-on rail mount.","salesMarkdown":"The A9F45425 is a Schneider Electric Acti9 iC60N miniature circuit breaker — 4 poles, 25 A rated current, D curve, thermal-magnetic trip. Breaking capacity reaches 36 kA Icu at 12…133 V AC, 20 kA at 220…240 V, and 10 kA at 380…415 V (all per IEC 60947-2); under IEC 60898-1 it carries 10 kA Icn at 415 V. That dual rating means it qualifies for both industrial (60947-2) and residential/commercial (60898-1) installations — useful when a panel crosses classification boundaries. Terminal accepts 1…25 mm² rigid or 1…16 mm² flexible; torque to 2 N·m. The 78.5 mm depth keeps it flush with other Acti9 devices in a row — no overhang on the enclosure door. Snap-on DIN-rail mounting inside a distribution board or industrial control panel. The 4-pole configuration handles three-phase plus neutral (or three-phase switched with a fourth pole for an additional phase). Pollution degree 3 (conductive pollution, typical in industrial enclosures) and tropicalisation class 2 per IEC 60068-1 mean it tolerates humidity up to 95 % at 55 °C without derating — suited for non-conditioned plant rooms or outdoor-rated enclosures. ## Coordination and selectivity note The separate earth-leakage block (Vigi iC60) clips onto the same busbar stack if ground-fault protection is required, without changing the breaker footprint.","metaTitle":"Schneider Electric A9F45425 iC60N MCB, D Curve, 25 A, 4P, 36","metaDescription":"Schneider Electric A9F45425 Acti9 iC60N miniature circuit breaker, 25 A, D curve, 4 poles, 36 kA breaking capacity at 133 V AC. Dual-rated to IEC 60947-2 and IEC 60898-1. Current l","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"D","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC/DC","Product name":"Disbo iC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"Rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","[In] rated current":"25 A","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 %","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1afc543ef020d5482bb17f394d7a678c.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9F45425/acti9-ic60n-4p-25a-d-miniature-circuit-breaker/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F45425/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9F45425 and get a price?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — submit an RFQ for a firm commercial offer."},{"question":"What is the breaking capacity of A9F45425 at 415 V?","answer":"10 kA Icu at 380…415 V AC per IEC 60947-2, and 10 kA Icn at 415 V per IEC 60898-1 — the same value under both standards at that voltage."},{"question":"What compliance documentation does Schneider provide for A9F45425?","answer":"The breaker is certified to EN/IEC 60947-2 and EN/IEC 60898-1. Pollution degree 3, tropicalisation class 2, and IP20 per IEC 60529 are documented. RoHS and REACH declarations are standard for the Acti9 range; request them with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F45425","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F45425 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}