{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F54340","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F54340","canonicalUrl":"https://aoctrl.com/schneider/A9F54340","factsUrl":"https://aoctrl.com/api/mcp/products/A9F54340","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60H miniature circuit breaker, A9F54340, 40 A, 3-pole, C curve, 30 kA breaking capacity.","salesMarkdown":"## Branch circuit protection for commercial and industrial panels The A9F54340 is a 3-pole 40 A C-curve miniature circuit breaker from the Acti9 iC60H range, built for branch circuit protection where both domestic (IEC 60898-1) and industrial (IEC 60947-2) approvals are needed. Breaking capacity hits 30 kA Icu at 240 V AC, 15 kA at 415 V AC under IEC 60947-2, and 10 kA Icn at 415 V under IEC 60898-1. The thermal-magnetic trip unit with a C curve (magnetic threshold 8 x In ±20%) covers common motor and lighting starts in panels rated for 40 A down to 1 mm² wire. Clip-on rail mount, IP20 front, padlockable handle, and a trip indicator.","metaTitle":"Schneider A9F54340 MCB, 40A 3P C-Curve, 30kA","metaDescription":"Schneider Acti9 iC60H MCB A9F54340, 40 A, 3-pole, C curve, 30 kA breaking capacity. Current production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"54 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC/DC","Product name":"Disbo iC60","Mounting mode":"Clip-on","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"Rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iC60H","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","[In] rated current":"40 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...35 mm² rigid Single terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Separate block","Provision for padlocking":"Padlockable","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Contact position indicator":"Yes","Locking options description":"Handle sealable with cable diameter 0.7mm in OFF or ON position","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","[Ue] rated operational voltage":"12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 180 V DC","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"21 kA 50 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 50 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$81.83","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e4bf6f5578ba471d1ded4cc93bc69918.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F54340/alternatives.json"},"ai":{"faq":[{"question":"What is A9F54340's listed depth (78.5 mm) on this component line?","answer":"Depth is 78.5 mm."},{"question":"What is A9F54340's listed range (Acti9) on this component line?","answer":"Range is Acti9."},{"question":"What compliance documentation does this brand provide for A9F54340 (RoHS, REACH, UL, IEC)?","answer":"Complies with EN/IEC 60898-1 and EN/IEC 60947-2 standards. RoHS and REACH compliance are not listed in this evidence."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F54340","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F54340 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}