{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F68116","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F68116","canonicalUrl":"https://aoctrl.com/schneider/A9F68116","factsUrl":"https://aoctrl.com/api/mcp/products/A9F68116","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iT60, A9F68116, miniature circuit breaker, 1P, 16 A, C-curve, 36 kA breaking capacity at 12-60 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F68116 is a 1-pole Acti9 iT60 miniature circuit breaker rated 16 A with a C-curve trip characteristic. ## Breaking capacity and application Rated breaking capacity reaches 36 kA Icu at 12-60 V AC (EN/IEC 60947-2), stepping down to 10 kA Icu at 220-240 V AC and 6 kA Icn at 230 V AC under the 60898-1 standard. This gives the A9F68116 headroom for high-fault panels where a standard 6 kA or 10 kA MCB would not coordinate. The C-curve (8 x In +/- 20% magnetic trip) suits moderate inrush loads such as small motor circuits, lighting banks, or distribution subfeeds. Removable comb busbar installed. Terminals accept 1-25 mm² rigid or 1-16 mm² flexible cable; tightening torque 2 N.m. IP20 B finger-safe protection. The thermal-magnetic trip unit is non-interchangeable — select the rating at BOM freeze.","metaTitle":"Schneider Electric A9F68116 Acti9 iT60 MCB, 16 A, C-Curve, 1","metaDescription":"Schneider Electric A9F68116 Acti9 iT60 miniature circuit breaker, 16 A rated, C-curve, 1-pole, 36 kA breaking capacity at 12-60 V AC. Certified to EN/IEC 60947-2 and 60898-1. Quote","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Range":"Acti9","Width":"18 mm","Colour":"White","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iT60","Mounting mode":"Removable comb busbar installed","Embedding depth":"44 mm","Tropicalisation":"2 conforming to EN/IEC 60068-2-78","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iT60N","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 %","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"16 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 B conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/dc2d811195baf50fb514a32077df1a4a.pdf","sourceUrl":"https://www.se.com/be/en/product/A9F68116/miniature-circuit-breaker-mcb-acti9-it60n-1p-16a-c-curve-6000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F68116/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9F68116 and how is it quoted for volume purchases?","answer":"A9F68116 is sourced through independent distribution channels. Availability and current pricing are confirmed at quote time against an RFQ; submit a request for volume pricing and lead time."},{"question":"What is A9F68116's rated current and trip curve?","answer":"The A9F68116 is rated 16 A with a C-curve (magnetic trip at 8 x In +/- 20%), suitable for moderate inrush loads."},{"question":"What compliance documentation does Schneider provide for A9F68116?","answer":"The A9F68116 carries dual certification to EN/IEC 60947-2 and EN/IEC 60898-1, with documented isolation suitability, pollution degree 3, overvoltage category IV, and tropicalisation class 2. A declaration of conformity is available from Schneider Electric."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F68116","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F68116 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}