{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F68306","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F68306","canonicalUrl":"https://aoctrl.com/schneider/A9F68306","factsUrl":"https://aoctrl.com/api/mcp/products/A9F68306","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iT60, A9F68306, miniature circuit-breaker, 6 A, C curve, 3 poles, 36 kA Icu at 133 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F68306 is a 6 A, 3-pole miniature circuit-breaker from the Acti9 iT60 range, carrying a C curve for moderate inrush loads like small motors or lighting circuits. Rated insulation voltage is 500 V AC, and the breaking capacity reaches 36 kA Icu at 133 V AC, stepping down to 10 kA at 400 V AC under the 60947-2 standard. The thermal-magnetic trip unit has a magnetic threshold of 8 x In ±20%. At 220–240 V AC the rating drops to 20 kA, and at 380–415 V AC it holds at 10 kA — sufficient for most European low-voltage distribution panels. The limitation class is 3, meaning it limits let-through energy effectively for downstream equipment protection. Snap-on DIN rail mounting per EN/IEC 60715. The 54 mm width (6 x 9 mm pitches) occupies three modular spaces in the panel. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; tightening torque is 2 N·m. The removable comb busbar is pre-installed for daisy-chaining phases.","metaTitle":"A9F68306 Acti9 iT60 MCB, 6 A, C Curve, 3P, 36 kA","metaDescription":"Schneider Electric A9F68306 Acti9 iT60 miniature circuit-breaker, 6 A rated current, C curve, 3 poles, 36 kA breaking capacity at 133 V AC. Dual certified to EN/IEC 60947-2 and 608","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"Acti9","Width":"54 mm","Colour":"White","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC/DC","Product name":"Acti9 iT60","Mounting mode":"Removable comb busbar installed","Tropicalisation":"2 conforming to EN/IEC 60068-2-78","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iT60N","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 %","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"6 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 B conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9F68306/miniature-circuit-breaker-mcb-acti9-it60n-3p-6a-c-curve-6000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F68306/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9F68306?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is A9F68306's breaking capacity at 400 V?","answer":"Under EN/IEC 60947-2 the Icu is 10 kA at 380–415 V AC; under EN/IEC 60898-1 the Icn is 10 kA at 400 V AC."},{"question":"What wire sizes does the A9F68306 terminal accept?","answer":"Single terminal accepts 1–25 mm² rigid or 1–16 mm² flexible wire, top or bottom. Strip length is 14 mm, tightening torque 2 N·m."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F68306","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F68306 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}