{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F68310","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F68310","canonicalUrl":"https://aoctrl.com/schneider/A9F68310","factsUrl":"https://aoctrl.com/api/mcp/products/A9F68310","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iT60, A9F68310, miniature circuit breaker, 10 A, C curve, 3 poles, 54 mm width, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F68310 is a 10 A, C-curve miniature circuit breaker from the Acti9 iT60 series, built for distribution boards where you need thermal-magnetic protection on a 3-pole AC/DC circuit. The 10 A rating sets the continuous current it carries without tripping; the C curve means magnetic trip occurs at 5 to 10 times rated current — 8 x In +/-20 % per the spec — so it handles moderate inrush from small motors or transformers without nuisance trips. Breaking capacity is the real differentiator here: 36 kA Icu at 133 V AC, 20 kA at 240 V, 10 kA at 415 V, and 6 kA at 440 V. That 10 kA at 415 V covers most European industrial panel fault levels; the 6 kA at 440 V is worth noting if your line runs 440 V three-phase — it's lower than the 415 V figure, so verify your prospective short-circuit current at that voltage. The removable comb busbar is pre-installed, so you can daisy-chain phases across adjacent breakers without extra wiring. Terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible; strip length is 14 mm, torque to 2 N·m. IP20 finger-safe for enclosed panels.","metaTitle":"Schneider Electric A9F68310 Acti9 iT60 MCB, 10 A, C Curve, 3","metaDescription":"Schneider Electric A9F68310 Acti9 iT60 miniature circuit breaker, 10 A rated current, C curve, 3 poles, 36 kA breaking capacity at 133 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"Acti9","Width":"54 mm","Colour":"White","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"6","Control type":"Toggle","Network type":"AC/DC","Product name":"Acti9 iT60","Mounting mode":"Removable comb busbar installed","Tropicalisation":"2 conforming to EN/IEC 60068-2-78","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iT60N","Network frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 %","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"10 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 B conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 180 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9F68310/miniature-circuit-breaker-mcb-acti9-it60n-3p-10a-c-curve-6000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F68310/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F68310 at 400 V?","answer":"At 400 V AC, the A9F68310 has a breaking capacity of 10 kA Icu per EN/IEC 60947-2 and 6 kA Icn per EN/IEC 60898-1. The 10 kA figure is the one to use for industrial panel design."},{"question":"What does the C curve mean on this breaker?","answer":"The C curve means the magnetic trip operates at 5 to 10 times the rated current — specifically 8 x In +/-20 %. This suits circuits with moderate inrush, like small motors, transformers, or lighting banks, where a B curve would nuisance-trip but a D curve would delay too long for cable protection."},{"question":"Where can I buy the A9F68310 and how is it quoted?","answer":"The A9F68310 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume or project needs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F68310","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F68310 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}