{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F68404","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F68404","canonicalUrl":"https://aoctrl.com/schneider/A9F68404","factsUrl":"https://aoctrl.com/api/mcp/products/A9F68404","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iT60 miniature circuit breaker, 4 A rated current, C-curve, 4 poles, 72 mm width, 50 kA breaking capacity at 415 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F68404 is an Acti9 iT60 miniature circuit breaker (MCB) rated at 4 A with a C-curve trip characteristic, 4 poles, and a 72 mm width on a DIN rail mount. ## Breaking capacity — what the 50 kA rating means for your panel This MCB carries a 50 kA Icu at 220…240 V AC and 380…415 V AC per EN/IEC 60947-2, and 25 kA Icu at 440 V AC. At 400 V AC it also meets 10 kA Icn per EN/IEC 60898-1. The C-curve (8 x In ±20 % magnetic trip) gives a 32 A instantaneous pickup, so it rides through inrush from small motors or capacitive loads without nuisance tripping. Snap-on DIN rail mount, 72 mm wide (8 x 9 mm pitches). Terminals accept 1…25 mm² rigid or 1…16 mm² flexible copper, with a 14 mm strip length and 2 N.m tightening torque. The removable comb busbar is pre-installed, so daisy-chaining phases across multiple MCBs in a row is straightforward — no extra busbar kit needed. IP20 finger-safe terminals, but the front face is not sealed; keep it inside a panel with a door.","metaTitle":"Schneider A9F68404 Acti9 iT60 MCB, 4A C-Curve 4P 50kA","metaDescription":"Schneider Electric A9F68404 Acti9 iT60 miniature circuit breaker, 4 A rated current, C-curve, 4 poles, 50 kA breaking capacity at 415 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Range":"Acti9","Width":"72 mm","Colour":"White","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC/DC","Product name":"Acti9 iT60","Mounting mode":"Removable comb busbar installed","Tropicalisation":"2 conforming to EN/IEC 60068-2-78","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iT60N","Network frequency":"50/60 Hz","Poles description":"4P","Relative humidity":"95 %","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"4 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...25 mm² rigid Single terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 B conforming to IEC 60529","Magnetic tripping limit":"8 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"50 kA 100 % conforming to EN/IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/be/en/product/A9F68404/miniature-circuit-breaker-mcb-acti9-it60n-4p-4a-c-curve-6000a-iec-en-608981-50ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F68404/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F68404 at 415 V?","answer":"50 kA Icu at 380…415 V AC per EN/IEC 60947-2."},{"question":"Where can I buy the A9F68404?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"Does the A9F68404 comply with EN/IEC 60898-1?","answer":"Yes, it is certified to both EN/IEC 60898-1 and EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F68404","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F68404 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}