{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9F78132","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9F78132","canonicalUrl":"https://aoctrl.com/schneider/A9F78132","factsUrl":"https://aoctrl.com/api/mcp/products/A9F78132","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iC60N, miniature circuit breaker, 32 A, B-curve, 1-pole, 36 kA breaking capacity at 12-60 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9F78132 is an Acti9 iC60N miniature circuit breaker — a 1-pole, 32 A, B-curve unit built for distribution panels where you need fast tripping on short circuits but a bit of headroom on inrush. The B-curve (4 x In magnetic trip limit, +/- 20 %) means it holds through moderate motor or transformer starts but clears quickly on a hard fault. For residential or light commercial branch circuits rated at 230 V, the IEC 60898-1 Icn is 6 kA, which is the standard domestic fault level. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible, with a 3.5 N.m torque spec. Strip length 14 mm. That 35 mm² top-end means you can land a fat feeder cable without pigtails. IP20 rated, so keep it behind a panel door or in a cabinet.","metaTitle":"Schneider Electric A9F78132 Acti9 iC60N MCB, 32 A, B-Curve,","metaDescription":"Schneider A9F78132 Acti9 iC60N miniature circuit breaker, 32 A, B-curve, 1-pole. 36 kA breaking capacity at 12-60 V AC. DIN rail. Active production. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60947-2 EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"DC AC","Product name":"Acti9 iC60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Trip indicator","Mounting support":"DIN rail","Pollution degree":"3 conforming to EN/IEC 60947-2","Breaking capacity":"36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"IC60N","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"32 A","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A conforming to EN/IEC 60947-2","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...35 mm² rigid Single terminal (top or bottom) 1...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"4 x In +/- 20 %","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1 Yes conforming to EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC 50/60 Hz conforming to EN/IEC 60947-2","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-35...70 °C","[Ics] rated service breaking capacity":"27 kA 75 % conforming to EN/IEC 60947-2 - 12...60 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 100...133 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 15 kA 100 % conforming to EN/IEC 60947-2 - 12...60 V DC 10 kA 100 % conforming to EN/IEC 60947-2 - 60...72 V DC","[Uimp] rated impulse withstand voltage":"6 kV conforming to EN/IEC 60947-2","Comb busbar and distribution block compatibility":"Top or bottom: YES"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/17a23d05f09e2a1bb6306b5f6b87fb27.pdf","sourceUrl":"https://www.se.com/be/en/product/A9F78132/miniature-circuit-breaker-mcb-acti9-ic60n-1p-32a-b-curve-6000a-iec-en-608981-10ka-iec-en-609472/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9F78132/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9F78132?","answer":"The breaking capacity is 36 kA Icu at 12-60 V AC, 20 kA at 100-133 V AC, 10 kA at 220-240 V AC (all per EN/IEC 60947-2), and 6 kA Icn at 230 V AC per EN/IEC 60898-1. For DC, it's 15 kA at 12-60 V DC and 10 kA at 60-72 V DC."},{"question":"Where can I buy the A9F78132?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What standards does the A9F78132 comply with?","answer":"It complies with EN/IEC 60947-2 and EN/IEC 60898-1, covering both industrial and household applications. It also meets IEC 60068-1 for tropicalisation (2 levels) and has pollution degree 3 rating per EN/IEC 60947-2."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9F78132","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9F78132 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}