{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9FDB610","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9FDB610","canonicalUrl":"https://aoctrl.com/schneider/A9FDB610","factsUrl":"https://aoctrl.com/api/mcp/products/A9FDB610","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iDPN N Arc, arc fault detection circuit breaker, 1P+N, 10 A, C curve, 6 kA Icn at 230 V AC, DIN rail clip-on.","salesMarkdown":"## Arc fault detection circuit breaker, 1P+N, 10 A, C curve The Schneider Electric A9FDB610 is an Acti9 iDPN N Arc arc fault detection circuit breaker (AFDD) — a single-module (36 mm wide) 1P+N device that combines overcurrent protection with series arc fault detection per IEC 62606. Rated 10 A at 30 °C with a C curve (magnetic trip 5...10 x In), it breaks 6000 A Icn at 230 V AC 50 Hz (IEC 60898-1). The thermal-magnetic trip unit handles both overload and short-circuit; the arc-fault electronics monitor the downstream circuit for dangerous series arcs and trip the breaker when detected. The 1P+N format (switched phase, switched neutral) isolates both poles on a fault, which is required in some national wiring regs. Limitation class 3 (IEC 60898-1) means it lets through less energy during a short-circuit, helping downstream selectivity. The 9 mm pitch between phase and neutral terminals matches the Acti9 busbar system. Tunnel-type terminals accept up to 16 mm² rigid or 10 mm² flexible (single cable), or 2 × 2.5 mm². IP20 finger-safe terminals. The toggle switch gives ON/OFF/trip indication. The A9FDB610 is listed as current production (active lifecycle). The Acti9 range is widely specified, so cross-referencing to a panel BOM is straightforward.","metaTitle":"Schneider Electric A9FDB610 Acti9 iDPN N Arc, 10A C-Curve AF","metaDescription":"Schneider Electric A9FDB610 Acti9 iDPN N Arc arc fault detection circuit breaker, 10A C-curve, 6kA breaking capacity, 1P+N, DIN rail mount. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"72 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"IEC 60898-1 EN/IEC 62606","Curve code":"C","Cable Entry":"Top","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iDPN N Arc","Mounting mode":"Clip-on","Tropicalisation":"Severity B conforming to IEC 60068-2-30 for 28 d","lifecycle_stage":"current","Connection pitch":"9 mm between phase and neutral","Limitation class":"3 conforming to IEC 60898-1","Local signalling":"ON, OFF, fault trip","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2","Breaking capacity":"6000 A Icn at 230 V AC 50 Hz conforming to EN/IEC 60898-1","Device short name":"iDPN N Arc","Network frequency":"50 Hz","Poles description":"1P + N","Tightening torque":"2 N.m","Operating altitude":"2000 m","[In] rated current":"10 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles 230 V AC 50 Hz","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm","Connections - terminals":"Tunnel type terminal for 1 cable(s) 10 mm² flexible Tunnel type terminal for 2 cable(s) 2.5 mm² flexible Tunnel type terminal for 1 cable(s) 16 mm² rigid Tunnel type terminal for 2 cable(s) 2.5 mm² rigid","IP degree of protection":"IP20","Magnetic tripping limit":"5...10 x In","Device location in system":"Outgoer","Number of protected poles":"1","Product or component type":"Arc fault detection circuit breaker","Contact position indicator":"Yes","Threshold tripping voltage":"400 V 200 ms","Product specific application":"Fire prevention by arc detection","[Ui] rated insulation voltage":"400 V AC","[Ue] rated operational voltage":"230 V AC 50 Hz conforming to IEC 62606 230 V AC 50 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Uimp] rated impulse withstand voltage":"4 kV conforming to IEC 60898-1","Comb busbar and distribution block compatibility":"ProDis Librio"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c7acfb84b5bc9b6254b987b66e936820.pdf","sourceUrl":"https://www.se.com/nz/en/product/A9FDB610/arc-fault-detection-circuit-breaker-acti9-idpn-n-arc-1p+n-10a-c-6000a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9FDB610/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9FDB610?","answer":"The A9FDB610 has a breaking capacity of 6000 A Icn at 230 V AC 50 Hz, conforming to EN/IEC 60898-1."},{"question":"Where can I buy the A9FDB610?","answer":"The A9FDB610 is available to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What standards does the A9FDB610 comply with?","answer":"The A9FDB610 complies with IEC 60898-1 and EN/IEC 62606 (arc fault detection)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9FDB610","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9FDB610 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}