{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9FDB7613","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9FDB7613","canonicalUrl":"https://aoctrl.com/schneider/A9FDB7613","factsUrl":"https://aoctrl.com/api/mcp/products/A9FDB7613","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric iDPN N Arc fire protection switch + LS, 2-pole, 13 A, B-curve, 6 kA breaking capacity, DIN rail mount.","salesMarkdown":"The A9FDB7613 is a 2-pole combination fire protection switch and miniature circuit breaker from the iDPN N Arc family. The thermal-magnetic trip mechanism handles both overloads (slow thermal) and faults (fast magnetic). Rated insulation voltage is 400 V, and the short-circuit breaking capacity (Icn) is 6 kA — enough for most final subcircuits in a 400/230 V distribution board. The overvoltage category III rating means it's designed for fixed installations inside the building's main panel, not for outlet-level use. It's 50 Hz only, so don't spec it for 60 Hz systems without checking the manufacturer's derating. DIN rail mount, 36 mm wide (2 modules), 81 mm tall, 72 mm deep. The tunnel terminals accept screw-clamp wiring up to 2 Nm torque. IP20 means it's for dry indoor panels only — no washdown, no dust. This is a panel-board part, not a field device.","metaTitle":"A9FDB7613 Fire Protection Switch, 2-Pole, 13 A, B-Curve, 6 k","metaDescription":"A9FDB7613 fire protection switch + LS (iDPN N Arc), 2-pole, 13 A, B-curve, 6 kA breaking capacity. DIN rail mount, 50 Hz, IP20. Current lifecycle stage. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"72 mm","Poles":"2","Width":"36 mm","title":"A9FDB7613","Height":"81 mm","Frequency":"50 Hz","IP Rating":"IP20","description":"Fire Protection Switch + LS, iDPN N Arc, 2 Poles, 13A, B, 6kA","Mounting Type":"DIN Rail Mount","Rated Current":"13 A","lifecycle_stage":"current","Tripping Mechanism":"Thermal Magnetic","Overvoltage Category":"III","Terminal Contact Type":"Tunnel Terminals","Rated Insulation Voltage":"400 V","Tripping Characteristics":"B","Tightening Torque - Screw-Type Max.":"2 Nm","Rated Short-Circuit Breaking Capacity Icn":"6 kA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$74.86 – $83.41","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6ad2020784a53bda05f31ba84265aa2a.pdf","sourceUrl":null},"ai":{"faq":[{"question":"What is the breaking capacity of the A9FDB7613?","answer":"The rated short-circuit breaking capacity Icn is 6 kA at 400 V, 50 Hz."},{"question":"What is the tripping characteristic of this breaker?","answer":"B-curve — trips magnetically between 3 and 5 times rated current (39 A to 65 A for this 13 A unit)."},{"question":"Can I use this on a 60 Hz system?","answer":"The listed frequency is 50 Hz. Using it on 60 Hz without manufacturer confirmation is not recommended."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9FDB7613","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9FDB7613 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}