{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K02263","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K02263","canonicalUrl":"https://aoctrl.com/schneider/A9K02263","factsUrl":"https://aoctrl.com/api/mcp/products/A9K02263","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60, miniature circuit-breaker, A9K02263, 2P, C-curve, 63 A, 6 kA Icn at 400 V AC, DIN-rail mount, IP20.","salesMarkdown":"The Schneider Electric A9K02263 is a 2-pole miniature circuit-breaker from the Acti9 K60 range, rated 63 A with a C-curve trip characteristic. It breaks 6 kA at 400 V AC per EN/IEC 60898-1, which covers most residential and light commercial distribution boards — the 6 kA rating is the standard for final subcircuits in a TN or TT system, so it coordinates downstream without requiring a higher-rated upstream device. Tightening torque is 3.5 N.m, and the wire strip length is 14 mm for both top and bottom connections. The 36 mm width (2 x 9 mm pitches) fits a standard 2-module slot in a distribution board. Electrical durability is 10,000 cycles, mechanical 20,000 cycles, and it operates at altitudes up to 2,000 m without derating.","metaTitle":"Schneider Electric A9K02263 Acti9 K60 MCB, 2P C-curve 63A, 6","metaDescription":"Schneider Electric A9K02263 Acti9 K60 miniature circuit-breaker, 2-pole, C-curve, 63 A rated current, 6 kA breaking capacity at 400 V AC, EN/IEC 60898-1. Available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"36 mm 18 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"2 4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60N","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"3.5 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"63 A 40 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 0.5...35 mm² rigid Tunnel type terminals (upstream) 0.5...35 mm² rigid Tunnel type terminals (downstream) 0.5...25 mm² flexible Tunnel type terminals (upstream) 0.5...25 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"440 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C -40...70 °C","Ambient air temperature for operation":"-25...70 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz","Comb busbar and distribution block compatibility":"Downside: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a6a93ee1511243429adee4615ebc64a9.pdf","sourceUrl":"https://www.se.com/sg/en/product/A9K02263/acti9-k60n-2p-63a-c-curve-6000-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K02263/alternatives.json"},"ai":{"faq":[{"question":"Who supplies A9K02263 and how is it quoted for volume purchases?","answer":"We source the A9K02263 through independent distribution and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for your volume and target price."},{"question":"What is A9K02263's listed depth (70 mm) on this component line?","answer":"The depth is 70 mm, with a height of 81 mm and a width of 36 mm (2 x 9 mm pitches). These dimensions fit standard DIN-rail enclosures and distribution boards."},{"question":"What compliance documentation does this brand provide for A9K02263 (RoHS, REACH, UL, IEC)?","answer":"The A9K02263 is certified to EN/IEC 60898-1 and carries an IP20 rating per IEC 60529. It is tropicalised per IEC 60068-1 (class 2). For RoHS, REACH, and UL documentation, contact us with your RFQ and we will provide the manufacturer's compliance declarations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K02263","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K02263 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}