{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K23116","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K23116","canonicalUrl":"https://aoctrl.com/schneider/A9K23116","factsUrl":"https://aoctrl.com/api/mcp/products/A9K23116","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60N, miniature circuit-breaker, 1P, 16 A, B curve, 6000 A Icn at 230 V AC, thermal-magnetic, clip-on DIN rail, IP20.","salesMarkdown":"The A9K23116 is a Schneider Electric Acti9 iK60N miniature circuit-breaker — a 1-pole, 16 A, B-curve thermal-magnetic MCB rated for AC distribution per EN/IEC 60898-1. If the panel ambient runs higher, derate per the manufacturer's curve. The 440 V AC rated insulation voltage (Ui) confirms the breaker is suitable for 230/400 V networks, though the breaking capacity is declared at 230 V only. Width is 18 mm (2 x 9 mm pitches), so it occupies one standard module position. Depth of 78.5 mm and height of 85 mm — verify enclosure depth clearance, particularly in shallow gland-plate or door-mount panels. Tunnel terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible; tighten to 2 N·m. Strip length 14 mm.","metaTitle":"A9K23116 Acti9 iK60N MCB, 1P B-curve 16 A, 6 kA","metaDescription":"Schneider Electric A9K23116 Acti9 iK60N miniature circuit breaker, 1-pole, 16 A, B-curve, 6 kA breaking capacity per EN/IEC 60898-1. Current production. Sourced to order against RF","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"1P","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K23116/miniature-circuit-breaker-mcb-acti9-ik60n-1p-16a-b-curve-6000a-iec-en-608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K23116/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9K23116?","answer":"The breaking capacity is 6000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 60898-1. This is the maximum fault current the breaker can safely interrupt under standard test conditions."},{"question":"What is the rated current and curve of A9K23116?","answer":"Rated current is 16 A at 30 °C ambient, with a B-curve (magnetic trip between 3 and 5 times In). The B-curve is suited for resistive and general-purpose loads with low inrush."},{"question":"Where can I buy A9K23116?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K23116","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K23116 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}