{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K23201","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K23201","canonicalUrl":"https://aoctrl.com/schneider/A9K23201","factsUrl":"https://aoctrl.com/api/mcp/products/A9K23201","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60N, A9K23201, miniature circuit breaker, 1 A, B-curve, 2P, 6 kA Icn at 400 V AC, thermal-magnetic, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9K23201 is an Acti9 iK60N miniature circuit breaker (MCB) rated at 1 A with a B-curve trip characteristic, 2 poles, and a 6 kA breaking capacity at 400 V AC. The 6 kA Icn at 400 V AC conforms to EN/IEC 60898-1, which is the standard for household and similar installations. This is a limitation class 3 device per the same standard, meaning it limits let-through energy enough to protect downstream equipment in a fault. The rated insulation voltage (Ui) is 440 V AC, so it's fine on 400 V line-to-line systems. ## Mounting and connections The 2-pole width is 36 mm (4 x 9 mm pitches). Tunnel-type terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible cable; tightening torque is 2 N.m. Rated for 10,000 electrical cycles and 20,000 mechanical cycles — typical for a distribution MCB. The toggle provides ON/OFF visual indication. Padlocking provision allows lockout/tagout.","metaTitle":"Schneider Electric A9K23201 Acti9 iK60N MCB, 1A B-Curve 2P 6","metaDescription":"Schneider Electric A9K23201 Acti9 iK60N miniature circuit breaker. 1A rated, B-curve, 2-pole, 6kA breaking capacity at 400V AC. EN/IEC 60898-1. Current lifecycle. Available to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"1 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Without","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K23201/miniature-circuit-breaker-ik60n-2p-1-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K23201/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9K23201?","answer":"The A9K23201 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9K23201?","answer":"The A9K23201 has a 6 kA Icn breaking capacity at 400 V AC 50/60 Hz, conforming to EN/IEC 60898-1. This is the standard rating for household and similar installations."},{"question":"What does the B-curve mean on this MCB?","answer":"The B-curve means the magnetic trip operates between 3 and 5 times the rated current (In). For the 1 A A9K23201, that's 3 to 5 A magnetic trip threshold. This curve is sized for resistive and light inductive loads with low inrush current."},{"question":"What compliance documentation does Schneider provide for A9K23201?","answer":"The A9K23201 is certified to EN/IEC 60898-1. It carries IP20 protection per IEC 60529. The product is part of the Acti9 range and is suitable for isolation per the standard. Specific RoHS/REACH/UL documentation should be verified against the manufacturer's current declarations at time of order."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K23201","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K23201 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}