{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K23206","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K23206","canonicalUrl":"https://aoctrl.com/schneider/A9K23206","factsUrl":"https://aoctrl.com/api/mcp/products/A9K23206","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60N, A9K23206, miniature circuit breaker, 2P, B-curve, 6 A, 6 kA Icn at 400 V AC, thermal-magnetic, DIN rail clip-on.","salesMarkdown":"The A9K23206 is a 2-pole miniature circuit breaker from the Acti9 iK60N series, rated 6 A at 30 °C with a B-curve trip characteristic (magnetic trip between 3 and 5 times In). The thermal-magnetic trip unit handles overloads (thermal bimetal) and short-circuits (solenoid) in one package, so no separate protection relay is needed for the branch circuit. Clip-on mounting to a 36 mm wide DIN-rail profile (4 module pitches at 9 mm each) means it snaps into the same panel footprint as any standard Acti9 or similar MCB. ## Deployment context This is a distribution MCB for AC branch circuits in a final sub-distribution board or consumer unit — think lighting, general-purpose socket outlets, or small motorized loads where the B-curve inrush tolerance is sufficient. The IP20 finger-safe terminals suit enclosed panel installation; the toggle actuator gives local ON/OFF indication and accepts a padlocking device for lockout/tagout during maintenance.","metaTitle":"Schneider Electric A9K23206 Acti9 iK60N MCB, 2P B-Curve 6A,","metaDescription":"Schneider Electric A9K23206 Acti9 iK60N miniature circuit breaker, 2-pole, B-curve, 6 A rated, 6 kA breaking capacity at 400 V AC. EN/IEC 60898-1. Current lifecycle. Quoted to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"2P","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"6 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Without","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K23206/miniature-circuit-breaker-mcb-acti9-ik60n-2p-6a-b-curve-6000a-iec-en-608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K23206/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9K23206?","answer":"The A9K23206 is rated for 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1, which is the standard fault-interruption rating for this class of miniature circuit breaker."},{"question":"What standards does A9K23206 comply with?","answer":"It is certified to EN/IEC 60898-1, with a limitation class of 3, pollution degree 2, and overvoltage category III. The suitability for isolation is also confirmed per that standard."},{"question":"Where can I buy A9K23206 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote — submit an RFQ for a firm commitment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K23206","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K23206 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}