{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K23601","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K23601","canonicalUrl":"https://aoctrl.com/schneider/A9K23601","factsUrl":"https://aoctrl.com/api/mcp/products/A9K23601","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60 miniature circuit-breaker, A9K23601, 1P+N, 1 A rated, B-curve, 6 kA breaking capacity at 230 V AC, thermal-magnetic trip, clip-on DIN rail mount.","salesMarkdown":"The Schneider Electric A9K23601 is a 1P+N miniature circuit-breaker from the Acti9 iK60 series, rated 1 A at 30 °C with a B-curve (magnetic trip between 3 and 5 x In). The 1 A rating and B-curve mean it trips fast on moderate overloads (3–5 x In), so it suits resistive loads like lighting strings or control transformers where inrush is low. Thermal-magnetic trip technology handles both sustained overload (thermal bimetal) and short-circuit (solenoid). It is also certified for isolation (EN/IEC 60898-1), meaning you can safely isolate the downstream circuit with the toggle in the OFF position. The 1P+N configuration switches the phase and switches the neutral (neutral left). Only the phase is protected — the neutral is switched but not monitored for overcurrent. IP20 finger-safe protection on the front; the terminals are protected when wired.","metaTitle":"Schneider Electric A9K23601 Acti9 iK60 MCB, 1A Curve B, 1P+N","metaDescription":"Schneider Electric A9K23601 Acti9 iK60 miniature circuit breaker, 1A rated current, B-curve, 1P+N, 6kA breaking capacity at 230V AC. EN/IEC 60898-1. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"B","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"1 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Single terminal (top or bottom) 1...25 mm² rigid","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"3...5 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad5302cd9c1ce7b869ad339b9756f11c.pdf","sourceUrl":"https://www.se.com/in/en/product/A9K23601/miniature-circuit-breaker-ik60n-1p-+-n-1-a-b-curve/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K23601/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9K23601?","answer":"The A9K23601 has a breaking capacity of 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1. This is the standard domestic/commercial fault level for this standard."},{"question":"What is the A9K23601 used for?","answer":"The A9K23601 is a miniature circuit-breaker for distribution applications — typically protecting lighting circuits, small control transformers, or resistive loads on a single-phase 230 V AC supply. The 1 A B-curve rating suits circuits with low inrush current."},{"question":"Where can I buy the A9K23601?","answer":"The A9K23601 is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment."},{"question":"What compliance standards does the A9K23601 meet?","answer":"The A9K23601 is certified to EN/IEC 60898-1 for miniature circuit-breakers, with limitation class 3. Rated insulation voltage 440 V AC, overvoltage category III, pollution degree 2. IP20 front protection per IEC 60529."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K23601","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K23601 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}