{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K24413","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K24413","canonicalUrl":"https://aoctrl.com/schneider/A9K24413","factsUrl":"https://aoctrl.com/api/mcp/products/A9K24413","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60N, miniature circuit-breaker, A9K24413, 4P, 13 A, C-curve, 6 kA Icn at 400 V AC, thermal-magnetic, clip-on DIN rail.","salesMarkdown":"The Schneider Electric A9K24413 is an Acti9 iK60N miniature circuit breaker (MCB) — a 4-pole, 13 A, C-curve device rated for AC distribution panels. At 72 mm wide for 4 poles (9 mm per pole × 8 pitches), it occupies 8 module spaces. Depth of 78.5 mm and height of 85 mm fit standard distribution board cutouts. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible; tighten to 2 N·m. IP20 finger-safe front — fine for enclosed panels; not for wet or outdoor locations.","metaTitle":"Schneider Electric A9K24413 Acti9 iK60N MCB, 13 A, 4P, C-Cur","metaDescription":"Schneider Electric A9K24413 Acti9 iK60N miniature circuit breaker, 13 A rated, 4-pole, C-curve, 6 kA breaking capacity at 400 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"4P","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"13 A at 30 °C","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"4","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K24413/miniature-circuit-breaker-mcb-acti9-ik60n-4p-13a-c-curve-6000a-iec-en-608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K24413/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for A9K24413?","answer":"Submit an RFQ through the storefront. The part is sourced to order via independent distribution; pricing and stock levels are confirmed at quote time — no deferred or manufacturer-contact step needed."},{"question":"What is A9K24413's listed depth?","answer":"78.5 mm — that is the body depth behind the panel face, not including the toggle throw."},{"question":"What compliance documentation does this brand provide for A9K24413?","answer":"The MCB is designed to EN/IEC 60898-1 and carries a pollution degree 2 rating and overvoltage category II. Isolation suitability is confirmed per the same standard. RoHS/REACH declarations and the CE declaration are part of the standard documentation package supplied with the part."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K24413","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K24413 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}