{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K24604","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K24604","canonicalUrl":"https://aoctrl.com/schneider/A9K24604","factsUrl":"https://aoctrl.com/api/mcp/products/A9K24604","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60N, A9K24604, miniature circuit-breaker, 4 A, C-curve, 1P+N, 6 kA Icn, EN/IEC 60898-1.","salesMarkdown":"The A9K24604 is a Schneider Electric Acti9 iK60N miniature circuit-breaker rated 4 A at 30 °C with a C-curve (magnetic trip 5...10 x In), meaning it's sized for general-purpose branch circuits where moderate inrush — from small motors, transformers, or lighting ballasts — is expected. The 1P+N configuration (one protected pole plus switched neutral) suits single-phase final subcircuits where the neutral is switched with the phase, common in UK/EU split-load boards. The thermal-magnetic trip unit provides overload protection via the bimetal and short-circuit protection via the solenoid, with the C-curve's 5-10x In window balancing nuisance-tripping against fault clearance. Clip-on mounting to DIN rail (35 mm per EN 60715) and a width of 36 mm (4 x 9 mm pitches) means it occupies one standard module slot in a distribution board — critical for panel fill-factor planning. The IP20 finger-safe terminals (tunnel type, accepting 1...25 mm² rigid or 1...16 mm² flexible) are rated for enclosure-only use; no washdown or outdoor exposure. The white colour and ON/OFF toggle indication are standard for Acti9 residential ranges. Limitation class 3 per that standard means it limits let-through energy effectively for downstream equipment protection. The suitability-for-isolation marking (yes, conforming to EN/IEC 60898-1) means it can be used as a disconnecting means for the circuit. No earth-leakage protection is integrated — that's handled by a separate RCD upstream.","metaTitle":"Schneider Electric A9K24604 Acti9 iK60N MCB, 4 A C-Curve 1P+","metaDescription":"Schneider Electric A9K24604 Acti9 iK60N miniature circuit-breaker, 4 A rated, C-curve, 1P+N, 6 kA breaking capacity, EN/IEC 60898-1. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"4 A at 30 °C","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K24604/miniature-circuit-breaker-mcb-acti9-ik60n-1p+n-4a-c-curve-6000a-iec-en-608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K24604/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9K24604 and what is the lead time?","answer":"The A9K24604 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time commitment."},{"question":"What is the closest alternative to A9K24604 in the Acti9 range?","answer":"Within the Acti9 iK60N family, the closest sibling is the A9K24204 (same 1P+N, C-curve, 6 kA, but rated 2 A instead of 4 A). The form factor, terminal capacity, and breaking capacity are identical — the only delta is the thermal-magnetic trip rating. If you need a higher current, the A9K24606 (6 A) or A9K24610 (10 A) share the same physical footprint and curve."},{"question":"What is A9K24604's depth?","answer":"The A9K24604 has a depth of 78.5 mm, a height of 85 mm, and a width of 36 mm (4 x 9 mm pitches)."},{"question":"What compliance documentation does Schneider provide for A9K24604?","answer":"The A9K24604 is designed and tested to EN/IEC 60898-1, the standard for AC miniature circuit-breakers. It carries limitation class 3, pollution degree 2, and overvoltage category II per that standard. The suitability-for-isolation marking confirms it meets the disconnection requirements of EN/IEC 60898-1. Standard Schneider documentation includes the declaration of conformity and test certificates available through their product documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K24604","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K24604 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}