{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K24606","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K24606","canonicalUrl":"https://aoctrl.com/schneider/A9K24606","factsUrl":"https://aoctrl.com/api/mcp/products/A9K24606","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60 miniature circuit breaker, A9K24606, 1P+N, 6 A rated current, C-curve, 6 kA breaking capacity at 230 V AC, thermal-magnetic trip, clip-on DIN rail mount.","salesMarkdown":"It is a 1-pole + neutral (1P+N) unit rated at 6 A at 30 °C, with a C-curve trip characteristic (magnetic tripping between 5 and 10 times the rated current). The thermal-magnetic trip unit provides overload protection (thermal bimetal) and short-circuit protection (magnetic coil) in a single device. ## Deployment context — panel integration The A9K24606 clips onto a standard 35 mm DIN rail (EN 60715) and occupies 4 x 9 mm pitches (36 mm width), leaving room for adjacent modules in a multi-row enclosure. The tunnel-type terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible cable; the recommended tightening torque is 2 N.m. Wire stripping length is 14 mm. The white housing carries an ON/OFF toggle indicator and a padlocking provision for lockout/tagout during maintenance.","metaTitle":"Schneider Electric A9K24606 Acti9 iK60 MCB, 1P+N, 6 A, C-Cur","metaDescription":"Schneider Electric A9K24606 Acti9 iK60 miniature circuit breaker, 1P+N, 6 A rated, C-curve, 6 kA breaking capacity at 230 V AC. EN/IEC 60898-1. Active production. Available to orde","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"6 A at 30 °C","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K24606/miniature-circuit-breaker-mcb-acti9-ik60n-1p+n-6a-c-curve-6000a-iec-en-608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K24606/alternatives.json"},"ai":{"faq":[{"question":"What is the A9K24606 used for?","answer":"It is a miniature circuit breaker for AC distribution boards, protecting downstream wiring and loads against overloads and short circuits. The 1P+N configuration switches the live conductor and provides a switched neutral, suitable for single-phase final circuits up to 6 A."},{"question":"Where can I buy the A9K24606 and get current pricing?","answer":"The A9K24606 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance standards does the A9K24606 meet?","answer":"It is certified to EN/IEC 60898-1, with a limitation class of 3, pollution degree 2, and overvoltage category II. It is suitable for isolation per the same standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K24606","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K24606 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}