{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K24625","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K24625","canonicalUrl":"https://aoctrl.com/schneider/A9K24625","factsUrl":"https://aoctrl.com/api/mcp/products/A9K24625","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60N, A9K24625, miniature circuit breaker, 1P+N, 25 A, C-curve, 6 kA Icn at 230 V AC, thermal-magnetic, DIN rail clip-on.","salesMarkdown":"## Acti9 iK60N — 25 A C-Curve MCB for Distribution Boards The Schneider Electric A9K24625 is a miniature circuit breaker from the Acti9 iK60N series, designed for AC distribution networks at 50/60 Hz. It is a single-pole-plus-neutral (1P+N) device rated 25 A at 30 °C with a C-curve trip characteristic (magnetic tripping limit 5...10 x In), making it suitable for protecting general-purpose circuits with moderate inrush currents — typical for lighting, socket outlets, and small motor loads in commercial and residential panels. Rated breaking capacity is 6000 A Icn at 230 V AC, conforming to EN/IEC 60898-1. The trip unit is thermal-magnetic: the thermal bimetal protects against sustained overloads, while the solenoid coil provides instantaneous magnetic protection on short-circuits. This 1P+N form factor saves one module width compared to a 2-pole breaker, which matters when filling a distribution board with multiple circuits. Dimensions are 85 mm height and 78.5 mm depth, fitting standard enclosure depths. The neutral is on the left side of the unit; the tunnel-type terminals accept 1...25 mm² rigid or 1...16 mm² flexible cable, with a tightening torque of 2 N.m and a strip length of 14 mm. IP20 rated for finger-safe installation inside an enclosed panel. Rated insulation voltage (Ui) is 440 V AC. Overvoltage category II and pollution degree 2 are standard for fixed-installation distribution boards. The toggle provides local ON/OFF indication; a padlocking device can be fitted for lockout/tagout procedures.","metaTitle":"A9K24625 Acti9 iK60N MCB, 25 A, C-Curve, 1P+N, 6 kA","metaDescription":"Schneider Electric A9K24625 Acti9 iK60N miniature circuit breaker, 25 A rated current, C-curve, 1P+N, 6 kA breaking capacity at 230 V AC. Current lifecycle stage. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"1P + N","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"25 A at 30 °C","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K24625/miniature-circuit-breaker-mcb-acti9-ik60n-1p+n-25a-c-curve-6000a-iec-en-608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K24625/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the A9K24625?","answer":"The breaking capacity is 6000 A Icn at 230 V AC, 50/60 Hz, conforming to EN/IEC 60898-1."},{"question":"What compliance documentation does Schneider provide for the A9K24625?","answer":"The breaker is certified to EN/IEC 60898-1. The manufacturer provides a declaration of conformity and datasheet covering the standard compliance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K24625","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K24625 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}