{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9K24716","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9K24716","canonicalUrl":"https://aoctrl.com/schneider/A9K24716","factsUrl":"https://aoctrl.com/api/mcp/products/A9K24716","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 iK60N miniature circuit-breaker, A9K24716, 3P+N, 16 A rated current, C-curve, 6 kA breaking capacity at 400 V AC, thermal-magnetic trip, clip-on DIN-rail mount.","salesMarkdown":"The Schneider Electric A9K24716 is an Acti9 iK60N miniature circuit-breaker (MCB) rated 16 A at 30 °C with a C-curve trip characteristic, built to EN/IEC 60898-1. The 6 kA Icn breaking capacity at 400 V AC 50/60 Hz means it can safely interrupt a fault current up to 6 000 A without welding the contacts — enough for most residential and light commercial distribution panels where the prospective short-circuit current stays under that level. The 3P+N configuration protects all three phases and switches the neutral, which is the standard arrangement for a three-phase distribution board in a TN or TT system. It clips onto a DIN rail, occupies 8 x 9 mm pitches (72 mm wide), and stands 85 mm tall with a depth of 78.5 mm, so it fits a standard modular enclosure without surprises. Mounting is clip-on DIN rail — no screws, just snap it onto the rail and it locks. The tunnel-type terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible wire; strip 14 mm and torque to 2 N·m. The toggle gives a clear ON/OFF indication, and there is a padlocking provision for lockout/tagout.","metaTitle":"Schneider Electric A9K24716 Acti9 iK60N MCB, 16 A, C-Curve,","metaDescription":"Schneider Electric A9K24716 Acti9 iK60N miniature circuit-breaker, 16 A rated current, C-curve, 3P+N, 6 kA breaking capacity at 400 V AC, EN/IEC 60898-1. Sourced to order against R","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Circuit Breaker Accessories"],"specifications":{"Depth":"78.5 mm","Range":"Acti9","Width":"72 mm","Colour":"White","Height":"85 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"8","Control type":"Toggle","Network type":"AC","Product name":"Acti9 iK60","Mounting mode":"Clip-on","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"ON/OFF indication","Mounting support":"DIN rail","Neutral position":"Left","Pollution degree":"2 conforming to EN/IEC 60898-1","Breaking capacity":"6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"iK60N","Network frequency":"50/60 Hz","Poles description":"3P + N","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","[In] rated current":"16 A at 30 °C","Overvoltage category":"III","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminal (top or bottom) 1...25 mm² rigid Tunnel type terminal (top or bottom) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"3","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Locking options description":"Padlocking device","[Ui] rated insulation voltage":"440 V AC 50/60 Hz conforming to EN/IEC 60898-1","Ambient air temperature for storage":"-40...85 °C","Ambient air temperature for operation":"-25...60 °C","[Ics] rated service breaking capacity":"6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV conforming to EN/IEC 60898-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9K24716/miniature-circuit-breaker-mcb-acti9-ik60n-3p+n-16a-c-curve-6000a-iec-en-608981/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9K24716/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9K24716?","answer":"The breaking capacity is 6000 A Icn at 400 V AC 50/60 Hz, conforming to EN/IEC 60898-1. This is the standard 6 kA rating for domestic and light commercial distribution boards."},{"question":"Where can I buy A9K24716?","answer":"The A9K24716 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is the rated current and curve of A9K24716?","answer":"The rated current is 16 A at 30 °C, with a C-curve trip characteristic (magnetic tripping between 5 and 10 times In). The C-curve is the standard choice for general-purpose loads like lighting, socket outlets, and small motor circuits."},{"question":"What compliance documentation does A9K24716 have?","answer":"The A9K24716 is certified to EN/IEC 60898-1, carries an IP20 degree of protection, and is suitable for isolation per that standard. It is a Schneider Electric Acti9 product, so full CE, UKCA, and RoHS documentation is available from the manufacturer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9K24716","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9K24716 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}