{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71101BQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71101BQ","canonicalUrl":"https://aoctrl.com/schneider/A9KF71101BQ","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71101BQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60 miniature circuit breaker, A9KF71101BQ, 1A rated current, C-curve, 10kA breaking capacity, 1P, 18mm wide, DIN rail mount.","salesMarkdown":"The Schneider Electric A9KF71101BQ is a 1A miniature circuit breaker from the Acti9 K60 series, built for distribution boards and sub-panels where a single-pole, C-curve thermal-magnetic trip protects a 1A branch circuit. The 18mm width (2 x 9mm pitches) fits a standard DIN-rail enclosure, and the IP20 finger-safe terminals accept up to 25mm² rigid or 16mm² flexible cable. The C-curve (magnetic trip at 5–10 x In) means this breaker holds through moderate inrush — typical for small transformers, lighting ballasts, or control-circuit power supplies — and trips fast on a hard short. The thermal-magnetic trip unit combines a bimetal strip for overload protection and a solenoid for short-circuit; no electronic adjustment, so it's a fit-and-forget part for fixed loads. ## Panel integration Snaps onto a standard 35mm DIN rail — no tools needed for mounting. The 18mm width occupies two 9mm module pitches, so plan for that footprint in your enclosure layout. Tunnel-type terminals accept 1–25mm² rigid or 1–16mm² flexible cable; strip 14mm and torque to 2 N·m for both line and load connections. The toggle control gives a clear visual on/off state. Operating altitude is 0–2000m; above that, derate the dielectric withstand. Pollution degree 2 covers normal indoor environments with only non-conductive contamination.","metaTitle":"Schneider Electric A9KF71101BQ Acti9 K60 MCB, 1A C-Curve, 10","metaDescription":"Schneider Electric A9KF71101BQ Acti9 K60 miniature circuit breaker, 1A rated, C-curve, 10kA breaking capacity per EN/IEC 60898-1. 1P, 18mm wide, DIN rail mount. Current lifecycle.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Quantity per set":"Set of 12","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"1 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71101BQ/acti-9-k60h-1p-1-a-c-curve-10-ka-set-of-12/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71101BQ/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9KF71101BQ and get a price?","answer":"The A9KF71101BQ is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time."},{"question":"What is the breaking capacity of A9KF71101BQ?","answer":"The A9KF71101BQ has a breaking capacity of 10,000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1."},{"question":"What standards does A9KF71101BQ comply with?","answer":"The A9KF71101BQ complies with EN/IEC 60898-1, the standard for miniature circuit breakers in household and similar installations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71101BQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71101BQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}