{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71102BQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71102BQ","canonicalUrl":"https://aoctrl.com/schneider/A9KF71102BQ","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71102BQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60H miniature circuit-breaker, A9KF71102BQ, 2 A rated current, C curve, 10 kA breaking capacity at 240 V AC, 1P, DIN rail mount.","salesMarkdown":"The A9KF71102BQ is a Schneider Electric Acti9 K60H miniature circuit-breaker, 1 pole, rated 2 A with a C curve and a 10 kA breaking capacity at 240 V AC per EN/IEC 60898-1. Thermal-magnetic trip unit, magnetic trip threshold 5 to 10 times In. Snaps onto DIN rail, 18 mm wide — fits a standard 2-module slot in a distribution board. The C curve means the magnetic trip activates between 5 and 10 times the rated current — so for a 2 A breaker, instantaneous trip starts at 10 A and is guaranteed by 20 A. Mounts on DIN rail, fixed position. Tunnel terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible copper; tighten to 2 N·m. Wire strip length 14 mm. The toggle actuator gives clear visual indication of tripped vs on/off state. IP20 finger-safe front, suitable for enclosed distribution boards.","metaTitle":"A9KF71102BQ Acti9 K60H MCB, 2 A, C Curve, 10 kA, 1P","metaDescription":"A9KF71102BQ Acti9 K60H miniature circuit-breaker, 2 A rated, C curve, 10 kA breaking capacity at 240 V AC, 1P, DIN rail, current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Quantity per set":"Set of 12","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"2 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71102BQ/acti-9-k60h-1p-2-a-c-curve-10-ka-set-of-12/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71102BQ/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy A9KF71102BQ?","answer":"Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm response."},{"question":"What is the breaking capacity of A9KF71102BQ?","answer":"10,000 A Icn at 240 V AC, 50/60 Hz, certified to EN/IEC 60898-1. That is the maximum fault current the breaker can safely interrupt under standard conditions."},{"question":"What compliance documentation does Schneider provide for A9KF71102BQ?","answer":"The breaker is certified to EN/IEC 60898-1, carries IP20 per IEC 60529, and meets tropicalisation class 2 per IEC 60068-1. RoHS and REACH declarations are standard for the Acti9 range; specific documentation is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71102BQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71102BQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}