{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71116","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71116","canonicalUrl":"https://aoctrl.com/schneider/A9KF71116","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71116","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60 miniature circuit breaker, A9KF71116, 16 A rated current, 1 pole, C-curve, 10 kA breaking capacity, DIN rail mount.","salesMarkdown":"The breaking capacity of 10,000 A Icn at 240 V AC (50/60 Hz) per EN/IEC 60898-1 tells you the breaker can safely interrupt a fault current up to 10 kA without welding or failing; this is the standard domestic and light commercial level for most panelboards. The 1-pole (1P) configuration protects a single phase. The IP20 rating means it is touch-safe but not sealed against moisture — suitable for indoor panel installation only. The pollution degree 2 rating confirms it is intended for normal, non-conductive environments (typical control cabinet). The 18 mm width (2 modules) means it occupies two 9 mm pitch positions in a distribution board — plan your rail fill accordingly.","metaTitle":"Schneider Electric A9KF71116 Acti9 K60 MCB, 16 A, 1P, C-Curv","metaDescription":"Schneider Electric A9KF71116 Acti9 K60 miniature circuit breaker, 16 A, 1P, C-curve, 10 kA breaking capacity, EN/IEC 60898-1. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"18 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"2","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Breaking capacity":"10000 A Icn at 240 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"1P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"16 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"1","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 240 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71116/acti9-k60h-1p-16-a-c-curve-10000-a/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71116/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9KF71116?","answer":"The breaking capacity is 10,000 A Icn at 240 V AC, 50/60 Hz, conforming to EN/IEC 60898-1."},{"question":"What compliance documentation does Schneider provide for A9KF71116?","answer":"The breaker is certified to EN/IEC 60898-1 and carries suitability for isolation marking. It also meets tropicalisation class 2 per IEC 60068-1 and pollution degree 2 per IEC 60947-1. RoHS and REACH declarations are standard for the Acti9 range."},{"question":"Where can I buy A9KF71116 and get current pricing?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71116","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71116 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}