{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71202BQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71202BQ","canonicalUrl":"https://aoctrl.com/schneider/A9KF71202BQ","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71202BQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60, A9KF71202BQ, miniature circuit breaker, 2P, C-curve, 2 A, 10 kA at 415 V AC.","salesMarkdown":"The A9KF71202BQ is a 2-pole miniature circuit breaker from the Schneider Electric Acti9 K60 series, rated 2 A with a C trip curve and a 10 kA breaking capacity at 415 V AC per EN/IEC 60898-1. It uses thermal-magnetic trip technology, with magnetic tripping between 5 and 10 times the rated current (5...10 x In), so it handles moderate inrush from lighting or small motor loads without nuisance trips. Rated for a 50/60 Hz AC network, it snaps onto a DIN rail and occupies 4 module pitches (36 mm wide) in the panel — a standard 2P width for distribution boards. The 10 kA Icn at 415 V AC is the short-circuit breaking capacity the breaker can safely interrupt under standard conditions per EN/IEC 60898-1 — enough for most commercial and light industrial distribution boards where the prospective fault current stays below that level. Terminals accept up to 25 mm² rigid or 16 mm² flexible conductors, and the tightening torque is 2 N.m for both top and bottom connections — standard for this class, no special tooling needed. IP20 finger-safe protection on the front, but the terminals are exposed once wired — standard for panel-mounted MCBs.","metaTitle":"A9KF71202BQ Acti9 K60 MCB, 2P C-curve 2A, 10kA","metaDescription":"A9KF71202BQ Acti9 K60 miniature circuit breaker, 2-pole, C-curve, 2A rated, 10kA breaking capacity at 415V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Quantity per set":"Set of 6","Breaking capacity":"10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"2 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71202BQ/acti-9-k60h-2p-2-a-c-curve-10-ka-set-of-6/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71202BQ/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9KF71202BQ?","answer":"10,000 A Icn at 415 V AC, 50/60 Hz, certified to EN/IEC 60898-1 — sufficient for most commercial distribution boards with fault levels under that threshold."},{"question":"What terminals does A9KF71202BQ accept?","answer":"Tunnel-type terminals: 1 to 25 mm² rigid or 1 to 16 mm² flexible on both upstream and downstream sides. Wire stripping length is 14 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71202BQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71202BQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}