{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"A9KF71206BQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"A9KF71206BQ","canonicalUrl":"https://aoctrl.com/schneider/A9KF71206BQ","factsUrl":"https://aoctrl.com/api/mcp/products/A9KF71206BQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric Acti9 K60 miniature circuit breaker, A9KF71206BQ, 6 A rated current, C-curve, 2-pole, 10 kA Icn at 415 V AC, DIN rail mount.","salesMarkdown":"The Schneider Electric A9KF71206BQ is a 6 A miniature circuit breaker from the Acti9 K60 series, 2-pole (2P), with a C-curve trip characteristic (magnetic tripping between 5 and 10 times In). It is rated for distribution applications and conforms to EN/IEC 60898-1. The 36 mm width (4 x 9 mm pitches) fits two-pole breakers in a compact footprint; 81 mm height and 70 mm depth leave clearance for typical enclosure depths. Tunnel terminals accept 1–25 mm² rigid or 1–16 mm² flexible wire; strip length 14 mm, tighten to 2 N·m.","metaTitle":"Schneider Electric A9KF71206BQ Acti9 K60 MCB, 6 A C-curve 2P","metaDescription":"Schneider Electric A9KF71206BQ Acti9 K60 miniature circuit breaker, 6 A rated current, C-curve, 2 poles, 10 kA breaking capacity at 415 V AC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"70 mm","Range":"Acti9","Width":"36 mm","Colour":"White","Height":"81 mm","Standards":"EN/IEC 60898-1","Curve code":"C","9 Mm Pitches":"4","Control type":"Toggle","Network type":"AC","Product name":"Acti9 K60","Mounting mode":"Fixed","Tropicalisation":"2 conforming to IEC 60068-1","lifecycle_stage":"current","Limitation class":"3 conforming to EN/IEC 60898-1","Local signalling":"Without","Mounting support":"DIN rail","Pollution degree":"2","Quantity per set":"Set of 6","Breaking capacity":"10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1","Device short name":"K60H","Network frequency":"50/60 Hz","Poles description":"2P","Relative humidity":"95 % at 55 °C","Tightening torque":"2 N.m top or bottom","Device application":"Distribution","Operating altitude":"0...2000 m","[In] rated current":"6 A","Overvoltage category":"II","Trip unit technology":"Thermal-magnetic","Electrical durability":"20000 cycles","Mechanical durability":"20000 cycles","Wire stripping length":"14 mm for top or bottom connection","Connections - terminals":"Tunnel type terminals (downstream) 1...25 mm² rigid Tunnel type terminals (upstream) 1...25 mm² rigid Tunnel type terminals (downstream) 1...16 mm² flexible Tunnel type terminals (upstream) 1...16 mm² flexible","IP degree of protection":"IP20 conforming to IEC 60529","Magnetic tripping limit":"5...10 x In","Earth-leakage protection":"Without","Number of protected poles":"2","Product or component type":"Miniature circuit-breaker","Suitability for isolation":"Yes conforming to EN/IEC 60898-1","Contact position indicator":"No","[Ui] rated insulation voltage":"500 V AC 50/60 Hz","Ambient air temperature for storage":"-25...85 °C","Ambient air temperature for operation":"-5...55 °C","[Ics] rated service breaking capacity":"7500 A 75 % conforming to EN/IEC 60898-1 - 415 V AC 50/60 Hz","[Uimp] rated impulse withstand voltage":"4 kV","Comb busbar and distribution block compatibility":"Downstream: biconnect"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/A9KF71206BQ/acti-9-k60h-2p-6-a-c-curve-10-ka-set-of-6/","alternativesUrl":"https://aoctrl.com/api/mcp/products/A9KF71206BQ/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of A9KF71206BQ?","answer":"10 kA Icn at 415 V AC, 50/60 Hz, conforming to EN/IEC 60898-1."},{"question":"What is the rated current and curve of this MCB?","answer":"6 A rated current, C-curve (magnetic trip between 5 and 10 times In)."},{"question":"Where can I buy A9KF71206BQ and how is it quoted?","answer":"This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does Schneider provide for A9KF71206BQ?","answer":"The MCB conforms to EN/IEC 60898-1 and is tropicalised per IEC 60068-1 (class 2). It is suitable for isolation per the same standard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/A9KF71206BQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/A9KF71206BQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}